User manual MINOLTA CM-5 BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MINOLTA CM-5. We hope that this MINOLTA CM-5 user guide will be useful to you.


MINOLTA CM-5 BROCHURE: Download the complete user guide (699 Ko)

You may also download the following manuals related to this product:

   MINOLTA CM-5 BROCHURE (1067 ko)
   MINOLTA CM-5 BROCHURE (1058 ko)
   MINOLTA CM-5 BROCHURE (1065 ko)

Manual abstract: user guide MINOLTA CM-5BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Spectrofotometer CM-5 Stand-alone Top-port Spectrofotometer met maximale flexibiliteit en veelzijdigheid Voeding & Ingrediënten Geneesmiddelen & Chemische producten Cosmetica & Parfums CM-5 biedt u veelzijdig gebruik De CM-5 Spectrofotometer met Top-Port en eenvoudige bediening! Het meten van de kleur van voeding, ingrediënten, smaak en -geurstoffen, dranken, geneesmiddelen en (basis) chemicaliën luistert vooral zeer nauw door de enorme diversiteit in vorm; van vaste stoffen tot poeder, korrels, pasta of vloeistof en de variatie tussen ondoorzichtige, doorschijnende of transparante monsters. De nieuwe functioneel ontworpen Spectrofotometer CM-5 van Konica Minolta kan het brede gamma van producten zonder meer aan. [. . . ] met de optionele adapter. Meting van vloeistoffen in transmissie Meting van vaste stoffen in transmissie Spectrofotometer Functies & eigenschappen die uw dagelijkse werk Het grote LCD scherm toont de meetresultaten, numeriek of grafisch, inclusief o. a. Om de bediening te vereenvoudigen is de "Operation Wizard" dé perfecte stap-voor-stap-gids op het scherm die u in 7 talen verder helpt. Om het gebruik door verschillende gebruikers op één CM-5 te vereenvoudigen kunnen meetgegevens en persoonlijke instellingen op een USB-stick worden opgeslagen. De ingebouwde software biedt naast de bekende colorimetrische evaluatiesystemen tevens de specifieke indexen uit de Industrie zoals Gardner, Jodium, Hazen (APHA), European Pharmacopoeia, en US Pharmacopoeia. sneller en eenvoudiger maken Top 10 Eigenschappen 1. High-endSpectrofotometermetbreedgolflenge-bereik Top-Portvoormetingenvanvastestoffeninreflectie Grotemeetkamervoormetingenvanvloeistoffenenvaste stoffen in transmissie Stand-alone functie met ingebouwd LCD scherm en Quality Control programma MetingvanIndustrie-specifiekeindexen Opslagvangebruikersinstellingenenmeetgegevensop eenUSB-stick "Operation Wizard" met stap-voor-stap instructies op het LCD scherm Ingebouwde programmatuur in 7 Talen Uiterstgemakkelijkebedieningmetautomatischecalibratie Compact, lichtgewicht en functioneel ontwerp Specifications Illumination/viewing system Spectrophotometer CM-5 Reflectance: Transmittance: di:8°, de:8° (diffuse illumination: 8° viewing) / SCI (specular component included)/SCE (specular component excluded) switchable Conforms to CIE No. 15, ISO 7724/1, ASTM E 1164, DIN 5033 Teil 7, and JIS Z 8722 (Condition c) di:0°, de:0° (diffuse illumination: 0° viewing) Integrating sphere size Detector Spectral separation device Wavelength range Wavelength pitch Half bandwidth Measurement range Light source Measurement time Measurement/ illumination area Ø152 mm Dual 40-element silicon photodiode arrays Planar diffraction grating 360 nm to 740 nm 10 nm Approx. 10 nm 0 to 175 % (Reflectance or transmittance); Output/display resolution: 0. 01% Pulsed Xenon lamp Approx. 3 s Reflectance: Transmittance: Changeable by changing mask and settings. LAV: Ø30 mm / Ø36 mm; MAV (optional): Ø8 mm / Ø11 mm; SAV (optional): Ø3 mm / Ø6 mm Ø20 mm Repeatability Inter-instrument agreement Transmittance chamber Display Display languages White calibration Interfaces Observer Illuminant Displayed data Color space Index Spectral reflectance: Standard deviation within 0. 1% (400 nm to 740 nm) / Chromaticity value: Standard deviation within E*ab 0. 04 * When a white calibration plate is measured 30 times at 10-second intervals after white calibration Within E*ab 0. 15 (Typical) I (Based on 12 BCRA Series II color tiles compared to values measured with a master body at 23°C) No sides (unlimited sample length); Depth (maximum sample thickness): 60 mm Sample holder (optional) for holding sheet samples or containers of liquid samples can be installed/removed 14. 5 cm TFT color LCD English, Japanese, German, French, Italian, Spanish, Simplified Chinese Automatic white calibration (reflectance) / 100% calibration (transmittance) using internal white calibration plate USB 1. 1 (Connection to PC; USB memory stick); RS-232C standard (Connection to serial printer) 2° Standard Observer or 10° Standard Observer A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65 (simultaneous evaluation with two light sources possible) Spectral values, spectral graph, colorimetric values, color-difference values, color-difference graph, pass/fail judgment, pseudo color, color assessment L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell, and color differences in these spaces (except for Munsell) Reflectance: Transmittance: MI; WI (ASTM E 313-73, ASTM E 313-96); YI (ASTM E 313-73, ASTM E 313-96, ASTM D 1925); ISO Brightness, B (ASTM E 313-73) Gardner, Iodine, Hazen (APHA), European Pharmacopoeia, US Pharmacopeia User index Color-difference equation Pass/fail judgment Storable data USB memory stick storage Power Size Weight Operating temperature/humidity range Storage temperature/humidity range User-defined index E*ab (CIE 1976), E*94 (CIE 1994), E00 (CIE 2000), E (Hunter), CMC (l: c) Tolerances can be set to colorimetric values (except Munsell), color-difference values, or reflectance index values Sample data: 4, 000 measurements; Target color data: 1, 000 measurements Storage of measurement data and target color data. Storage/reading of measurement condition settings (Security-en-abled USB memory sticks cannot be used. ) AC 100 to 240 V, 50/60 Hz (using exclusive AC adapter) Slide cover closed: 385 (W) × 192 (H) × 261 (D) mm I Slide cover open: 475 (W) × 192 (H) × 261 (D) mm Approx. 5. 8 kg 13 to 33°C, relative humidity 80 % or less (at 35°C) with no condensation 0 to 40°C, relative humidity 80 % or less (at 35°C) with no condensation < System Configuration > Target Mask (Ø3 mm) CM-A195 Target Mask (Ø8 mm) CM-A196 Connecting Cable CM-A58 AC Adapter Dust Cover CM-A191 CM-A205 CM-A210 CM-A124 CM-A203 CM-A128 CM-A212 CM-A193 Transmittance CM-A206 Measurement Set · Transmittance Zero Calibration Plate CM-A213 · Transmittance Specimen Holder CM-A96 · Transmittance Specimen Holder CM-A199 Attachment · Accessory Case CM-A193 Spectrophotometer CM-5 10 mm Cell CM-A207 Measurement Set · Transmittance Specimen Holder (10 mm) CM-A198 · Transmittance Zero Calibration CM-A204 Plate (10 mm) 10 mm-wide cell (Commercial product) CM-S100w Standard accessories USB Cable (2 m) IF-A19 SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument. · Always connect the instrument to the specified power supply voltage. [. . . ] SE Sales Division SE Beijing Office SE Guangzhou Office Singapore Seoul Office · Zero Calibration Box · Target Mask (for Petri Dish) · Petri Dish · Calibration Glass (for Petri Dish) · Accessory Case (with CD-ROM containing calibration data and data-setting software) Personal computer (Commercial product) Data printer (Commercial product) Cell CM-A97 (2 mm) Cell CM-A98 (10 mm) Cell CM-A99 (20 mm) Plastic Cell Plastic Cell Plastic Cell CM-A131 CM-A130 CM-A132 (2 mm; 100 pcs. ) (10 mm; 100 pcs. ) (20 mm; 100 pcs. ) Specimen Viewing Mirror Transmittance Mask CM-A202 CM-A200 (Ø20 mm) Optional accessories Distribuidor para España y Portugal Konica Minolta (CHINA) Investment Ltd. Nieuwegein, Netherland München, Germany Roissy CDG, France Milton Keynes, United Kingdom Milan, Italy Dietikon, Switzerland Västra Frölunda, Sweden Zaventem, Belgium Wien, Austria Wroclaw, Poland Valencia, Spain Shanghai, China Beijing, China Guangzhou, China Seoul, Korea Konica Minolta Sensing Singapore Pte Ltd. Konica Minolta Sensing, Inc. Phone: 888-473-2656 (in USA), 201-236-4300 (outside USA) Phone: +31(0)30 248-1193 Phone: +49(0)89 4357 156 0 Phone: +33(0)1 493-82519 Phone: +44(0)1908 540-622 Phone: +39 02 39011. 425 Phone: +41(0)43 322-9800 Phone: +46(0)31 7099464 Phone: +32 (0)2 7170 933 Phone: +43(0)1 87882-430 Phone: +48(0)71 33050-01 Phone: +34 963 30 20 13 Phone: +86-021-5489 0202 Phone: +86-010-8522 1551 Phone: +86-020-3826 4220 Phone: +65 6563-5533 Phone: +82(0)2-523-9726 Fax: +31(0)30 248-1280 Fax: +49(0)89 4357 156 99 Fax: +33(0)1 493-84771 Fax: +44(0)1908 540-629 Fax: +39 02 39011. 223 Fax: +41(0)43 322-9809 Fax: +46(0)31 474945 Fax: +32 (0)2 7170 977 Fax: +43(0)1 87882-431 Fax: +48(0)71 734 52 10 Fax: +34 963 30 03 96 Fax: +86 -021-5489 0005 Fax: +86-010-8522 1241 Fax: +86-020-3826 4223 Fax: +65 6560-9721 Fax: +82(0)2-523-9729 Certificate No: YKA 0937 154 Registration Date: March 3, 1995 Certificate No: JQA-E-80027 Registration Date: March 12, 1997 ©2009 KONICA MINOLTA www. konicaminolta. eu [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MINOLTA CM-5




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MINOLTA CM-5 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.