User manual MITSUBISHI AG-150A V1.2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MITSUBISHI AG-150A. We hope that this MITSUBISHI AG-150A user guide will be useful to you.


MITSUBISHI AG-150A V1.2: Download the complete user guide (6101 Ko)

You may also download the following manuals related to this product:

   MITSUBISHI AG-150A WEB BROWSER FOR INITIAL SETTINGS (1686 ko)

Manual abstract: user guide MITSUBISHI AG-150AV1.2

Detailed instructions for use are in the User's Guide.

[. . . ] Air-conditioner Control System Centralized Controller Model: AG-150A 1. 5. Instruction Book Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Product features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Initial Start up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] For example, if you wish to prohibit operations being performed from the remote controller after 17:00, set a Prohibit operation for 17:00 and set an Enable operation for 23:59. (Refer to 5-3-1 (1). ) (2) Set the contents of the schedule Touch the schedule content button on the current day schedule screen to bring up the schedule content setting screen. Make the settings for the execution time and operation patterns (ON/OFF, operation mode, setting temperature, airflow direction, fan speed, remote controller operation prohibition) on the schedule content setting screen, and then touch the [OK] button. The settings for only the operation mode or the setting temperature, for example, can be made. Note: When setting a schedule for all groups or for a block, it is possible to set all operation modes such as Auto mode etc, but if some targeted air conditioner units do not have such a function, then those units will not run in the specified mode. When setting the schedule, consider what functions are supported by the air conditioner units. Note: When setting a schedule for all groups or for a block, it is possible to set prohibit remote controller items individually. When allowing remote controller operation under K control, however, all items must be set enable. Note: When setting a schedule for ventilator units, the temperature setting is not displayed. Moreover, the prohibit remote controller operation is simply [ON/OFF]. Note: Only the ON/OFF operation is possible on the general equipment. (Air Conditioner) Refer to 5-3-1 (3) for the figure of LOSSNAY and Air To Water Booster unit. ­ 31 ­ (3) Copy a schedule to another group To copy the settings of the current day schedule in one group to another, select the group from the current day schedule setting screen (Floor layout or block display screen), touch [Copy], select a group to copy the schedule to, and touch [Paste]. * The settings of one type of equipment cannot be copied to the settings of a different type of equipment. (i. e. , The settings of air conditioning units cannot be copied to ventilation equipment settings. ) * Available operation modes and setting temperature range varies with models. (4) Save the contents of schedule After all the settings have been made, touch the [OK] button to save the schedule settings. Touch the [Cancel] button to go back to the previously saved settings without making any changes. ­ 32 ­ 5-4 Checking the List of Malfunctioning Units Touch the [Status list] in the main operation screen menu, and then touch [Malfunction] to see a list of units that are currently in error. Note: If an error occurs, check the unit address, error code and error description before consulting your dealer or service center. 3Unit address The unit address is displayed here. 4Number of malfunctioning units The number of malfunctioning units is displayed here. 5Error code The error code is displayed here. 6All reset Item 1Floor name or Block name Description The name of the floor or block that the unit in error belongs to appears here. * If a unit, such as an indoor unit or system controller, has not been registered in a group that is the object of the operation, this area will be blank. * If the unit in error has not been registered in a block or floor, this area will be blank. Note: If a unit, such as an outdoor unit or system controller, has not been registered in a group that is the object of the operation, this area will be blank. The error code of the error that is causing the malfunction is displayed. Touch [All Reset] when you want to reset the errors on all the malfunctioning units at once. If "All reset" is touched, the units that are reset will stop. 2Group Name 3Unit address 4Number of malfunctioning units The number of malfunctioning units is displayed. [. . . ] External input/output function · External signal input requires the external I/O adapter (PAC-YG10HA-E; sold separately). · Refer to the AG-150A Installation Manual for details. 11-1 External input function (1) The function of external input Touch [Initial Settings] on the menu bar in the setting change window, then [Network setting] to bring up the network settings window. Touch [External Input Setting], and make the settings. · The type of external input function can be selected by making certain settings. 1 2 3 4 Function of external input signal External input signal not used Perform emergency stop with level signal Perform ON/OFF operation with level signal Perform ON/OFF operation, prohibit/permit operation with pulse signal Remarks During emergency stop, only ON/OFF of the centralized controller and local remote controller operation will be prohibited. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MITSUBISHI AG-150A




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MITSUBISHI AG-150A will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.