User manual MITSUBISHI HS 1024E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MITSUBISHI HS 1024E. We hope that this MITSUBISHI HS 1024E user guide will be useful to you.


MITSUBISHI HS 1024E : Download the complete user guide (476 Ko)

You may also download the following manuals related to this product:

   MITSUBISHI HS 1024E (488 ko)

Manual abstract: user guide MITSUBISHI HS 1024E

Detailed instructions for use are in the User's Guide.

[. . . ] TIME LAPSE VIDEO CASSETTE RECORDER MODEL INSTALLATION AND OPERATION MANUAL Only video cassette tapes with the mark may be used with this model. This instruction manual is important to you. Please read it before using your video cassette recorder. PìCCäàâ DEUTSCH HS-1024E(E) ENGLISH This Time Lapse Video Cassette Recorder complies with the requirements of the EC Directive 89/336/EEC, "EMC Directive" and 73/ 23/EEC, "Low Voltage Directive", as amended by Directive 93/68/EEC. The requirements for the susceptibility according to EN 55024 and the requirements for interference according to EN 55022 are observed for the operation on residential areas, business, light industrial premises and in small scale enterprises, inside as well as outside of the building. All places of operation are characterised by their connection to the public low voltage power supply system. [. . . ] Turn JOG to select WRNG·TAPE END and turn SHUTTLE to the right. · <REAR TERMINAL> CALL OUT WRNG CLOCK OUT REC- 1 MODE OUT REC REC IN REC-START/STOP <REAR TERMINAL> CALL OUT WRNG CLOCK OUT REC- 1 MODE OUT REC REC IN REC-START/STOP Repeat Recording With this function, when the tape reaches its end during recording, the VCR rewinds the tape and starts recording again. · <MAIN MENU> appears. <MAIN MENU> DISPLAY TIMER PROGRAM RECORDING SET UP REAR TERMINAL MAINTENANCE CLOCK/FIRST TIME SET UP <FIRST TIME SET UP> TIME DATE ADJUST TAPE END STOP QUASI V-SYNC ON VIDEO MODE COLOUR TAPE LENGTH E-180 BUZZER WRNG <REAR TERMINAL> CALL OUT WRNG·TAPE END CLOCK OUT REC- 1 MODE OUT REC REC IN REC-START/STOP <REAR TERMINAL> CALL OUT WRNG CLOCK OUT REC- 1 MODE OUT REC REC IN REC-START/STOP <REAR TERMINAL> CALL OUT CLOCK OUT MODE OUT REC IN 2. Turn JOG to select CLOCK/FIRST TIME SET UP and turn SHUTTLE to the right. · <FIRST TIME SET UP> menu appears. WRNG REC- 1 REC SERIES The day and present time display appears on screen. 3. Turn JOG to select TAPE END and turn SHUTTLE to the right. <FIRST TIME SET UP> TIME DATE ADJUST TAPE END STOP QUASI V-SYNC ON VIDEO MODE COLOUR TAPE LENGTH E-180 BUZZER WRNG <FIRST TIME SET UP> TIME DATE ADJUST TAPE END REPEAT QUASI V-SYNC ON VIDEO MODE COLOUR TAPE LENGTH E-180 BUZZER WRNG Series Recording 2 Series Recording 2 provides a function: when the first VCR's tape reaches its end, the second VCR automatically begins recording. When the tape in second VCR finishes, the first VCR starts recording again. (The two VCRs keep recording one after another. ) Setup both 1st and 2nd VCRs as in the steps below. 1. · <MAIN MENU> appears. <MAIN MENU> DISPLAY TIMER PROGRAM RECORDING SET UP REAR TERMINAL MAINTENANCE CLOCK/FIRST TIME SET UP <FIRST TIME SET UP> TIME DATE ADJUST TAPE END STOP QUASI V-SYNC ON VIDEO MODE COLOUR TAPE LENGTH E-180 4. Turn JOG to select REPEAT or ALARM·PROT and turn SHUTTLE to the right. · The day and present time display appears on screen. When the tape reaches its end during recording The following functions are automatically engaged when the tape ends during recording. TAPE END setting When there are alarm recordings on tape The tape stops. (*) When there is NO alarm recording on tape The tape is rewound automatically to the beginning and then recording is resumed. 3. Turn JOG to select CLOCK/FIRST TIME SET UP and turn SHUTTLE to the right. Turn JOG to select REWIND and turn SHUTTLE to the right. <FIRST TIME SET UP> TIME DATE ADJUST TAPE END STOP QUASI V-SYNC ON VIDEO MODE COLOUR TAPE LENGTH E-180 <FIRST TIME SET UP> TIME DATE ADJUST TAPE END REWIND QUASI V-SYNC ON VIDEO MODE COLOUR TAPE LENGTH E-180 ALARM· PROT STOP REWIND The tape stops. The tape is rewound automatically to the beginning (except in timer recording) and then stops. The tape is rewound automatically to the beginning and then recording is resumed (also recording over existing alarms). 6. page 20 for series recording connection Note REPEAT · Timer or emergency recording function cannot be used with series recording at the same time. * To repeat recording on the same tape again, eject the tape once and reinsert. Reference page Advanced Functions 13 ENGLISH Additional Features Memory backup in case of power failure This VCR includes a built-in backup memory, so the preset day and present time will remain in memory even if there is a power failure. However, if the power cord is disconnected for a long period of time (2-3 months), the present time may not be accurate. In this case, set the clock again. Info. Clearing the power loss list 1. Select POWER LOSS LIST CLEAR in <MAINTENANCE> menu and turn SHUTTLE to the right. · Once the list is cleared, the Power Loss indicator ( ) will go off. POWER LOSS LIST CLEAR Turn the SHUTTLE RING then POWER LOSS LIST will be cleared. · · The battery is fully charged if the VCR's power cord is plugged into the outlet for 40 or more hours per week. If the battery is fully charged, even if the power cord is not plugged in, the following settings will remain in memory for up to 31 days: ­ The day and present time display ­ Alarm list ­ Power loss list ­ Number of tape uses ­ Counter display ­ Recording/Playback mode Note Displaying/clearing the alarm list Displaying the alarm list The alarm recording start time are logged in the VCR's Alarm List. · <MAINTENANCE> POWER LOSS LIST ALARM LIST ALL MENU INITIALISE POWER LOSS LIST CLEAR ALARM LIST CLEAR <REPEAT REC TIMES> <ELAPSED TIME> 0 0H · When ALARM REC DURATION of the RECORDING SET UP menu is set to MAN1 or MAN2 and a power failure occurs during the alarm recording, the VCR may not return to the alarm recording mode when the power comes back on. After a power failure If a power failure occurs during manual, 01-01-'01 MON timer or alarm recording, the VCR will 00:00:00 X L24 return to the recording mode when the power comes back on. [. . . ] The picture vibrates at the top and bottom when in still picture mode. Clear camera pictures during recording but during playback the picture is not clear. 28 Others Note A point to notice Info. Supplementary information Warning Display Self-diagnostic function ENGLISH This VCR uses a self-diagnostic function to detect an internal malfunction during recording. When a malfunction occurs in the VCR during recording, the indicator corresponding to each malfunction illuminates on the fluorescent display and/or on screen. The type of malfunction corresponding to the indicator and countermeasures are given below. Fluorescent display Monitor TAPE END Cause The tape ends during recording. Remedy Rewind the tape or press the EJECT button Check for loose connections. To turn off the indicator Turn off the indicator on the fluorescent display and screen by pressing the EJECT button or rewinding the tape. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MITSUBISHI HS 1024E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MITSUBISHI HS 1024E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.