User manual MITSUBISHI MDS-D-SV J3 SPECIFICATIONS MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MITSUBISHI MDS-D-SV J3. We hope that this MITSUBISHI MDS-D-SV J3 user guide will be useful to you.


MITSUBISHI MDS-D-SV J3 SPECIFICATIONS MANUAL: Download the complete user guide (4340 Ko)

Manual abstract: user guide MITSUBISHI MDS-D-SV J3SPECIFICATIONS MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Other company and product names that appear in this manual are trademarks or registered trademarks of their respective companies. Introduction Thank you for selecting the Mitsubishi numerical control unit. This instruction manual describes the handling and caution points for using this AC servo/spindle. Incorrect handling may lead to unforeseen accidents, so always read this instruction manual thoroughly to ensure correct usage. In order to confirm if all function specifications described in this manual are applicable, refer to the specifications for each CNC. Notes on Reading This Manual (1) Since the description of this specification manual deals with NC in general, for the specifications of individual machine tools, refer to the manuals issued by the respective machine manufacturers. [. . . ] Selection of Peripheral Devices 5-1 Selection of wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 5-1-1 Example of wires by unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 5-2 Selection of no-fuse breaker and contactor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4 5-2-1 Selection of no-fuse breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4 5-2-2 Selection of contactor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5 5-3 Selection of earth leakage breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6 5-4 Branch-circuit protection (for control power supply). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7 5-4-1 Circuit protector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7 5-4-2 Fuse protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7 5-5 Noise filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8 5-6 Surge absorber. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9 5-7 Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Selection of Peripheral Devices 5-1 Selection of wire 5-1-1 Example of wires by unit Selected wires must be able to tolerate rated current of the unit's terminal to which the wire is connected. How to calculate tolerable current of an insulated wire or cable is shown in "Tolerable current of electric cable" (1) of Japanese Cable Makers' Association Standard (JCS)-168-E (1995), its electric equipment technical standards or JEAC regulates tolerable current, etc. When exporting wires, select them according to the related standards of the country or area to export. In the UL standards, certification conditions are to use wires of 60 oC and 75 oC product. (UL508C) Wire's tolerable current is different depending on conditions such as its material, structure, ambient temperature, etc. Check the tolerable current described in the specification of the wire to use. (1) 600V vinyl insulated wire (IV wire) 60oC product (Example according to IEC/EN60204-1, UL508C) Terminal name Unit type Spindle drive unit MDS-D-SPJ3-075 MDS-D-SPJ3-22 MDS-D-SPJ3-37 MDS-D-SPJ3-55 MDS-D-SPJ3-75 MDS-D-SPJ3-110 MDS-D-SVJ3-03 MDS-D-SVJ3-04 MDS-D-SVJ3-07 MDS-D-SVJ3-10 MDS-D-SVJ3-20 MDS-D-SVJ3-35 CNP1 (L1, L2, L3, ) 2 mm AWG 2 14 2 14 2 14 3. 5 12 5. 5 10 14 6 2 14 2 14 2 14 2 14 2 14 3. 5 12 CNP2 (L11, L21) 2 mm AWG CNP3 (U, V, W, ) 2 mm AWG 2 14 2 14 3. 5 12 3. 5 12 5. 5 10 8 8 2 14 2 14 2 14 2 14 3. 5 12 5. 5 10 CNP2 (P, C) 2 mm AWG 2 14 3. 5 12 Magnetic brake 2 mm AWG 2 14 Servo drive unit 2 14 2 14 2 14 (2) 600V double (heat proof) vinyl insulated wire (HIV wire) 75 oC product (Example according to IEC/EN60204-1, UL508C) Terminal name Unit type Spindle drive unit MDS-D-SPJ3-075 MDS-D-SPJ3-22 MDS-D-SPJ3-37 MDS-D-SPJ3-55 MDS-D-SPJ3-75 MDS-D-SPJ3-110 MDS-D-SVJ3-03 MDS-D-SVJ3-04 MDS-D-SVJ3-07 MDS-D-SVJ3-10 MDS-D-SVJ3-20 MDS-D-SVJ3-35 CNP1 (L1, L2, L3, ) 2 mm AWG 2 14 2 14 2 14 3. 5 12 5. 5 10 8 8 2 14 2 14 2 14 2 14 2 14 2 14 CNP2 (L11, L21) 2 mm AWG CNP3 (U, V, W, ) 2 mm AWG 2 14 2 14 3. 5 12 3. 5 12 5. 5 10 8 8 2 14 2 14 2 14 2 14 2 14 5. 5 10 CNP2 (P, C) 2 mm AWG 2 14 3. 5 12 Magnetic brake 2 mm AWG 2 14 Servo drive unit 2 14 2 14 2 14 5-2 5. Selection of Peripheral Devices (3) 600V bridge polyethylene insulated wire (IC) 105oC product (Example according to JEAC8001) Terminal name Unit type Spindle drive unit MDS-D-SPJ3-075 MDS-D-SPJ3-22 MDS-D-SPJ3-37 MDS-D-SPJ3-55 MDS-D-SPJ3-75 MDS-D-SPJ3-110 MDS-D-SVJ3-03 MDS-D-SVJ3-04 MDS-D-SVJ3-07 MDS-D-SVJ3-10 MDS-D-SVJ3-20 MDS-D-SVJ3-35 CNP1 (L1, L2, L3, ) 2 mm AWG 2 14 2 14 2 14 2 14 3. 5 12 5. 5 10 2 14 2 14 2 14 2 14 2 14 2 14 CNP2 (L11, L21) 2 mm AWG CNP3 (U, V, W, ) 2 mm AWG 2 14 2 14 2 14 3. 5 12 5. 5 10 5. 5 10 2 14 2 14 2 14 2 14 2 14 3. 5 12 CNP2 (P, C) 2 mm AWG 2 14 3. 5 12 Magnetic brake 2 mm AWG 1. 25 16 Servo drive unit 1. 25 16 2 14 1. 25 16 CAUTION 1. To use the wire under conditions other than above, check the standards you are supposed to follow. If the wiring distance between the drive unit and motor is 20m or longer, use a thick wire so that the cable voltage drop is 2% or less. [. . . ] LTDA. ) ACESSO JOSE SARTORELLI, KM 2. 1 18550-000 BOITUVA ­ SP, BRAZIL TEL: +55-15-3363-9900 FAX: +55-15-3363-9911 ASEAN FA Center (MITSUBISHI ELECTRIC ASIA PTE. LTD. ) Singapore CNC Service Center 307 ALEXANDRA ROAD #05-01/02 MITSUBISHI ELECTRIC BUILDING SINGAPORE 159943 TEL: +65-6473-2308 FAX: +65-6476-7439 Thailand MITSUBISHI CNC Agent Service Center (F. CITY BUILDING OFFICE TOWER 1 FLOOR 12, 14 RAMA III RD BANGPONGPANG, YANNAWA, BANGKOK 10120. THAILAND TEL: +66-2-682-6522 FAX: +66-2-682-6020 Malaysia MITSUBISHI CNC Agent Service Center (FLEXIBLE AUTOMATION SYSTEM SDN. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MITSUBISHI MDS-D-SV J3




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MITSUBISHI MDS-D-SV J3 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.