User manual MITSUBISHI MXZ-2D33VA-E2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MITSUBISHI MXZ-2D33VA-E2. We hope that this MITSUBISHI MXZ-2D33VA-E2 user guide will be useful to you.


MITSUBISHI MXZ-2D33VA-E2 : Download the complete user guide (14093 Ko)

Manual abstract: user guide MITSUBISHI MXZ-2D33VA-E2

Detailed instructions for use are in the User's Guide.

[. . . ] Air-Conditioners OUTDOOR UNIT MXZ-8A140VA utilized HFC R410A INSTALLATION MANUAL INSTALLATIONSHANDBUCH MANUEL D?INSTALLATION INSTALLATIEHANDLEIDING MANUAL DE INSTALACIN MANUALE DI INSTALLAZIONE EXEIPIIO OHIN EKATA?TA?H?MANUAL DE INSTALAO INSTALLATIONSMANUAL INSTALLATIONSMANUAL MONTAJ ELK?TABI ???????????????????? FOR INSTALLER For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. Safety precautions s Before installing the unit, make sure you read all the ?Safety precautions?. [. . . ] 4 Fully close the gas stop valve when the pressure reading on the gauge drops to 0. * If too much refrigerant has been added to the air conditioner system, the pressure may not drop to 0. If this occurs, use a refrigerant collecting device to collect all of the refrigerant in the system, and then recharge the system with the correct amount of refrigerant after the indoor and outdoor units have been relocated. When commercially available copper pipes are used, wrap liquid and gas pipes with commercially available insulation materials (heat-resistant to 100 C or more, thickness of 12 mm or more). The indoor parts of the drain pipe should be wrapped with polyethylene foam insulation materials (specific gravity of 0. Apply thin layer of refrigerant oil to pipe and joint seating surface before tightening flare nut. Use leak detector or soapy water to check for gas leaks after connections are completed. 8 C IPipe size (Outdoor unit-Branch box) Pipe size (mm) Liquid Gas 9. Cm IPipe size (Branch box-Indoor unit) *Case of M series or S series Indoor unit Indoor unit type Pipe size (mm) (kW) Liquid Gas 22 6. 88 * When using 60 type indoor unit of MEXZ series, use the flare nut in the indoor unit accessory for the gas side connecting of indoor unit. IPipe size (Branch box-Indoor unit) *Case of P series indoor unit Indoor unit type Pipe size (mm) (kW) Liquid Gas 35 6. 88 When using 35, 50 type indoor unit of P series, use the flare nut attached to the indoor unit. 2 Flare the liquid pipes and gas pipes and apply a thin layer of refrigeration oil (Applied on site). When usual pipe sealing is used, refer to Table 2 for flaring of R410A refrigerant pipes. 88 (5/8") A (mm) Flare tool for R410A Flare tool for R22 5-6) Remove the service panel D (three screws) and the front piping cover A (two screws) and rear piping cover B (two screws). The pipes can be protectively wrapped up to a diameter of 90 before or after connecting the pipes. Cut out the knockout in the pipe cover following the groove and wrap the pipes. Use putty or sealant to seal the pipe inlet around the pipes so that no gaps remain. (If the gaps are not closed, noise may be emitted or water and dust will enter the unit and breakdown may result. Conduct piping connection and valve operation accurately by following the figure below. Apply sealer along the insulator to prevent water entering the insulator covering the refrigerant pipe joints. After evacuation and refrigerant charge , ensure that the handle is fully open. [. . . ] Korrektionsmngde for pfyldning af ekstra klemiddel ?R=0, 01 [kg/m] 9, 52 forgreningsrr (vskerr) samlet lngde [m] Eksempel) b1=20 m, b2=25 m Indendrsenhed A Indendrsenhed B Indendrsenhed C Indendrsenhed D 9, 52 Vskerr 6, 35 Vskerr 6, 35 Vskerr 9, 52 Vskerr a1=12 m a2=11 m a6=14 m a7=13 m Samlet rrlngde : b1+b2+a1+a2+a6+a7=95 m ?I henhold til skema 1 er mngden for pfyldning af ekstra klemiddel 3, 2 kg. da der er tilsluttet indendrsenheder med 9 , 52 vskerr (i dette eksempel indendrsenhed A og D) , skal mngden for pfyldning af ekstra klemiddel korrigeres. Korrektionsmngde for pfyldning af ekstra klemiddel ?R=0, 01 [kg/m] 9, 52 forgreningsrr (vskerr) totallngde (a1+a7) =0, 01 (12+13 m) =0, 25 kg Mngden for pfyldning af ekstra klemiddel er derfor 3, 2 kg + 0, 25 kg = 3, 45 kg. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MITSUBISHI MXZ-2D33VA-E2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MITSUBISHI MXZ-2D33VA-E2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.