User manual MITSUBISHI PKH36FK3

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MITSUBISHI PKH36FK3. We hope that this MITSUBISHI PKH36FK3 user guide will be useful to you.


MITSUBISHI PKH36FK3 : Download the complete user guide (880 Ko)

Manual abstract: user guide MITSUBISHI PKH36FK3

Detailed instructions for use are in the User's Guide.

[. . . ] Air-Conditioners PLH18, 24, 30, 36, 42AK PL12, 18, 24, 30, 36, 42AK PCH24, 30, 36, 42GK PC24, 30, 36, 42GK PKH18, 24, 30, 36FK3 PK12, 18, 24, 30, 36FK3 PKH18, 24, 30, 36FL PK18, 24, 30, 36FL3 FOR USER OPERATION read this operation manual thoroughly before operating the air-conditioner unit. Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Switching the unit on/off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · The airflow direction can not be set with UP/DOWN while the SWING setting is being used. · The arrow indicators are alternately displayed when the air sweep is in operation, however they are not displayed when the air sweep is not in operation. · The left/right guide vanes of PC(H) series and the guide vane of the PK(H) serises can be changed manually. 2. 6. Using the timer COOL CHECK TEST MODEL RUN DRY SELECT AUTO FAN SWING FAN HEAT NOT AVAILABLE °F °C STOP AMPM 1) Set the current time ON/OFF ­ CENTRALLY CONTROLLED DRY COOL TIMER OFF TIMER CLOCK AUTO AUTO FAN AUTO FAN CHECK SET TEMP. START STOP SPEED HEAT STAND BY DEFROST 1 Press clock/timer button to display the "CLOCK" B. Remote controller display A CLOCK START AMPM SWING °F AUTO RETURN FILTER CHECK MODE TEST RUN ON/OFF TEMP °F NOT AVAILABLE AUTO START AUTO No Display STOP FAN MODE VANE AUTO STOP AUTO START h min 1 MODE TIMER ON/OFF CLOCK/TIMER FAN SPEED AIR DISCHARGE FILTER 2 Each time you press TIMER SET button, the time increases in increments of one minute. Each time you press · Press and hold the button to rapidly change the time. · The time changes in increments of one minute ten minutes in units of hour; in this order. · Approximately ten seconds after pressing the button, the display on the remote controller will turn off. TIMER SET CHECK LOUVER TEST RUN SET RESET CLOCK AIR SWEEP CHECK SET TEMP. REMOTE CONTROLLER TIMER SET TEST RUN 1 (For Wireless Remote Controller) 1 Press the CLOCK button using a thin stick and blink the time A. (For Wireless Remote Controller) Press the AUTO START SET TEMP. REMOTE CONTROLLER TIMER SET TEST RUN or AUTO STOP to cancel the timer and repeat from 2) or 3). 4 3. Care and cleaning I PLH/PL Series Caution: · Always turn off the power, first on the remote controller and then the main switch, before cleaning or servicing the unit. · When installing or removing the filter or the intake grille, do not stand on an unsteady surface. I PLH/PL Series A B C Intake grille removal · Pull the knob on the intake grille in the direction indicated by the arrow and it should open. · Unhook the hinges to remove the intake grille from the grille. D Filter removal · Open the intake grille. · Release the knob on the center edge of the intake grille and pull the filter forward to remove the filter. A Knob B Grille C Intake grille D Filter I PCH/PC Series I PCH/PC Series · Open the intake grille. · Hold the knob on the filter then pull the filter up in the direction of an arrow. To replace the filter after cleaning, be sure to insert the filter far enough until it fits into the stopper. A B A Filter B Intake Grille C Knob D Stopper I PKH/PK Series · Hold the filter lug (located at the bottom of the intake grill) and pull it out downward. · To install the filters, push the filter lug upward. A Filter B Lug D C I PKH/PK Series B A 3. 1. Cleaning the filters and the indoor unit Cleaning the filters · Clean the filters using a vacuum cleaner. If you do not have a vacuum cleaner, tap the filters against a solid object to knock off dirt and dust. · If the filters are especially dirty, wash them in lukewarm water. Take care to rinse off any detergent thoroughly and allow the filters to dry completely before putting them back into the unit. [. . . ] Auxiliary heater A (kW) Airflow Dry CFM Lo-Hi Wet CFM W in Dimensions D in H in W in Dimensions D in (GRILLE) H in Weight lbs Weight (GRILLE) lbs OUTDOOR UNIT MODELS External finish Power supply V, Phase, Hz Max. Crankcase heater A (W) Refrigerant control Defrost method W in Dimensions D in H in Weight lbs REMOTE CONTROLLER Control voltage (by built-in transformer) NOTES: 20 15 0. 7 7. 7/8. 3 [1. 6/1. 9] 530-710 490-670 710-990 670-950 33-1/16 33-1/16 10-3/16 37-3/8 37-3/8 1-3/16 57 PUH18EK PUH24EK 71 11 PUH30EK Munsell 5Y 7/1 208/230, 1, 60 30 20 0. 65+0. 65 NH33NBD 11. 5 54 11-3/4 1. 2 9. 1/10. 4 [1. 9/2. 4] 25 17 1. 4 11. 1/12. 2 [2. 3/2. 8] 780-1060 740-1020 75 PUH36EK PUH42EK7 20 16 0. 75 RH247NAB 12. 0 37 0. 11/0. 17 (23/28) 22 34-1/4 11-5/8 33-1/2 131 202 0. 75+0. 75 NH41NAD NH47NAD 14. 0 17. 5 73 87 0. 16/0. 17 (33/39) Capillary tube Reverse cycle 38-3/16 13-9/16 49-9/16 245 246 With grille 40 28 0. 8+0. 8 ZR42K3-PFV 20. 4 109 246 Indoor unit-remote controller DC12V, Indoor unit- outdoor unit DC12V *1 Rating conditions (cooling) ­ indoor: 80°F DB. 15°F WB *3 Heating capacity and power consumption in [ ] include auxiliary electric heater operation at 208/230V. Units should be installed by licensed electric contractor accordingly to local code requirement. Specifications Item Models PL24AK PL30AK PL36AK PL42AK 24, 000 31, 000 36, 500 42, 500 2. 65 3. 17 3. 64 4. 08 10. 0 10. 6 10. 5 10. 8 PL24AK PL30AK PL36AK PL42AK Galvanized sheets with gray heat insulation Munsell 0. 7Y 8. 59/0. 97 115, 1, 60 15 2. 0 3. 0 1. 2 2. 6 420-560 530-710 710-990 780-1060 390-530 490-670 670-950 740-1020 33-1/16 33-1/16 10-3/16 11-3/4 37-3/8 37-3/8 1-3/16 49 53 66 71 11 PU12EK PU18EK PU24EK PU30EK PU36EK PU42EK7 Munsell 5Y 7/1 208/230, 1, 60 15 20 30 40 11 16 20 22 28 0. 65 0. 75 0. 65+0. 65 0. 75+0. 75 0. 8+0. 8 RH167NAB RH247NAB NH33NBD NH41NAD NH47NAD ZR42K3-PFV 8. 9 12. 0 11. 5 14. 0 17. 5 20. 4 29 37 54 73 87 109 0. 11/0. 12 (23/28) 0. 16/0. 17 (33/39) Capillary tube 34-1/4 38-3/16 11-5/8 13-9/16 25-9/16 33-1/2 49-9/16 105 154 207 220 220 With grille Indoor unit-remote controller DC12V, Indoor unit- outdoor unit DC12V PL12AK 12, 500 1. 26 10. 1 PL12AK PL18AK 18, 400 1. 85 10. 2 PL18AK Cooling capacity *1 BTU/h Power consumption *1 kW SEER INDOOR UNIT MODELS External finish External finish (GRILLE) Power supply V, Phase, Hz Max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MITSUBISHI PKH36FK3




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MITSUBISHI PKH36FK3 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.