User manual MITSUBISHI UD8350LU

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MITSUBISHI UD8350LU. We hope that this MITSUBISHI UD8350LU user guide will be useful to you.


MITSUBISHI UD8350LU : Download the complete user guide (10669 Ko)

You may also download the following manuals related to this product:

   MITSUBISHI UD8350LU (10752 ko)
   MITSUBISHI UD8350LU BROCHURE (1989 ko)

Manual abstract: user guide MITSUBISHI UD8350LU

Detailed instructions for use are in the User's Guide.

[. . . ] DLPTM PROJECTOR MODEL UD8400U UD8400LU UD8350U UD8350LU User Manual UD8400 UD8350 This User Manual is important to you. Please read it before using your projector. U CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. WARNING: CAUTION: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. TO PREVENT ELECTRIC SHOCK, DO NOT USE THIS (POLARIZED) PLUG WITH AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE. NOTE: SINCE THIS PROJECTOR IS PLUGGABLE EQUIPMENT, THE SOCKET-OUTLET SHALL BE INSTALLED NEAR THE EQUIPMENT AND SHALL BE EASILY ACCESSIBLE. [. . . ] SET NETWORK PASSWORD IP CONFIG DHCP IP ADDRESS ENTER ENTER ON / OFF ***. ***. ***. *** SET SUBNET MASK ***. ***. ***. *** SET DEFAULT GATEWAY ***. ***. ***. *** SET MAC ADDRESS NETWORK CERTIFICATION CONTROL SYSTEM xx-xx-xx-xx-xx-xx ON / OFF STANDARD AMX CRESTRON NETWORK RESET OK FUNCTION Displays PROJECTOR NAME. (See page 49. ) Set the password for Web control or PJLink certification. (See page 50. ) Use this setting when you obtain IP CONFIG automatically by DHCP server. However, IP ADDRESS is not set as factory default, and cannot be displayed. However, SUBNET MASK is not set as factory default, and cannot be displayed. However, DEFAULT GATEWAY is not set as factory default, and cannot be displayed. (See page 51. ) Select this setting when using ProjectorView Global+ or ProjectorView. (See pages 51 and 58. ) Select this setting when using the controller or software of Crestron Electronics, Inc. (See page 52. ) EN-40 Menu operation (continued) INFORMATION menu opt. 1 2 INFORMATION LAMP 1 TIME (LOW) LAMP 2 TIME (LOW) NEXT LAMP RELAY FILTER TIME SERIAL NUMBER INPUT RESOLUTION VERTICAL FREQUENCY HORIZONTAL FREQUENCY RGB H V ****H ****H *D **H *****H / ****TIMES ********. . . COMPUTER1 1024 x 768 60. 00 Hz 48. 36 kHz 5WIRE SYNC. TYPE ITEM LAMP 1 TIME (LOW) LAMP 2 TIME (LOW) NEXT LAMP RELAY FILTER TIME SERIAL NUMBER INPUT RESOLUTION VERTICAL FREQUENCY HORIZONTAL FREQUENCY SYNC. TYPE DESCRIPTION This item shows the lamp operation time calculated based on that the LAMP MODE of LAMP 1 is LOW. · WhentheLAMPMODEisSTANDARD, thisitemshowsalongerlampoperatingtimethan the actual time. · Whenthelampoperatingtimeis0to10hours, "0H"isdisplayed. Thelampoperatingtime exceeding 10 hours is indicated by the actual hours. · Whenthelampoperatingtimereaches3000hours, thebarturnstoyellow. Whenit reaches 3800 hours, the bar turns to red. Yellow: On, Red: End of lamp life or error such as illumination failure, Black: Off This item shows the lamp operation time calculated based on that the LAMP MODE of LAMP 2 is LOW. · WhentheLAMPMODEisSTANDARD, thisitemshowsalongerlampoperatingtimethan the actual time. · Whenthelampoperatingtimeis0to10hours, "0H"isdisplayed. Thelampoperatingtime exceeding 10 hours is indicated by the actual hours. · Whenthelampoperatingtimereaches3000hours, thebarturnstoyellow. Whenit reaches 3800 hours, the bar turns to red. Yellow: On, Red: End of lamp life or error such as illumination failure, Black: Off The next lamp relay time is displayed. Indicates the name of the terminal to which the currently projected video signal is being input. Indicates the vertical frequency of the currently projected video signal. Indicates the horizontal frequency of the currently projected video signal. [. . . ] · The projector's maximum resolution is 1920 x 1200 pixels. It may not display images of higher resolutions than 1920 x 1200 correctly. · Images with SYNC on G (Green) signal may be tinged with green. · If the resolution and frequency of your computer aren't shown on the table, find the compatible resolution and frequency by changing the resolution of your computer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MITSUBISHI UD8350LU




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MITSUBISHI UD8350LU will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.