User manual PANASONIC PAWDHWM120ZNT

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PANASONIC PAWDHWM120ZNT. We hope that this PANASONIC PAWDHWM120ZNT user guide will be useful to you.


PANASONIC PAWDHWM120ZNT : Download the complete user guide (3460 Ko)

Manual abstract: user guide PANASONIC PAWDHWM120ZNT

Detailed instructions for use are in the User's Guide.

[. . . ] The appliance may be used by children older than 8 years old, elderly persons and persons with physical, sensory or mental disabilities or lacking experience and knowledge, if they are under supervision or taught about safe use of the appliance and if they are aware of the potential dangers. Children should not clean or maintain the appliance without supervision. Always transport the heat pump in an upright position; exceptionally, it may be tilted by 35° in all directions. Be careful not to damage the housing or the vital component parts of the heat pump during transport. [. . . ] 11: LCD touch screen Legend: 1 - Signalization of the operation of solar 11 - TIMER start and setup collectors** 12 - Time setup and display 2 - alternative source of heating turned on 13 - Start-up of quick heating "TURBO" (heaters) 14 - Indicator of the heating element 3 - Signalization of the operation of the oil operation boiler** 15 - Start-up of heating to the maximum 4 - Indication, overview of operation temperature level errors, entrance into the service menu 16 - Signalization of compressor 5 - Display and setup of temperature in operation °C 17 - Signalization of anti-legionella 6 - Start and setup of the VACATION programme operation programme 18 - Warm water quantity display 7 - Day of the week 19 - Signalization of defrosting (1 . Sunday) 20 - Signalization of fan operation 8 - Reducing the value 9 - Heat pump on/off switch ** function is not used in versions 10 - Increasing the value TC-ZNT Starting/stopping the heat pump  To start the heat pump hold field no. When the appliance is switched on, the fan starts first and operates for one minute (symbol no. If the temperature of inlet air is appropriate, the controlling unit switches on the compressor and the heat pump operates in normal 17 EN mode (symbols 16 and 20 are displayed). In 60 seconds after the last touch of the screen, the illumination and activity of the screen are turned off, but that does not affect the operation of the heat pump. Pressing anywhere on the screen re-activates the screen and its illumination. If trying to start up at a lower temperature, please see chapter "Operation at lower temperatures". The appliance stops functioning and the only field visible on the screen is field no. (If you switch off the heat pump for a longer period of time, the water must be drained from the pump if there is any danger of freezing). Power failure protection In case of power failure, the settings remain stored for up to 23 hours. After restarting, the heat pump operates in the same mode it was operating in before the power failure. Operation at lower temperatures When the appliance is switched on, the fan starts first and operates for one minute (symbol no. If the temperature of inlet air is lower than -7 °C, the fan is turned off. The possibility of switching to normal mode is checked every 2 hours by switching on the fan for one minute. If the temperature of inlet air is higher than -7 °C, the heat pump switches to normal mode of operation (symbols 16 and 20 are displayed). At lower air temperatures, the evaporator defrosting cycle is started if necessary. Defrosting takes place until the conditions for normal operation of the heat pump are achieved. After successful defrosting, the heat pump returns to normal operation (symbols 16 and 20 are displayed). If defrosting is unsuccessful after two consecutive attempts, the controlling unit displays an error message. 12 and the pump switches automatically to heating with electric heaters. Setting the clock and day of the week  7 shows a flashing number of the day of the week.  By pressing + or – you can set the number of the day of the week (1 – Monday, …, 7 – Sunday). [. . . ] 11: LCD-berøringsskjerm Forklaring: 1 - Signalregulering for betjening av 13 - Start av hurtigoppvarming "TURBO" solfangere** 14 - Indikator for driften av 2 - Alternativ varmekilde er slått på varmeelementet (varmere) 15 - Oppstart av oppvarming til maks. 3 - Signalregulering for betjening av temperaturnivå oljevarmer** 16 - Signalregulering av kompressordrift 4 - Indikasjon, oversikt over driftsfeil, 17 - Signalregulering av driften av antitilgang til servicemeny legionellaprogram 5 - Visning og oppsett av temperatur i °C 18 - Mengdevisning for varmt vann 6 - Start og oppsett av FERIE-program 19 - Signalregulering av tining 7 - Ukedag 20 - Signalregulering av viftedrift (1 . (Hvis du slår av varmepumpen for en lengre periode må pumpen tømmes for vann slik at det ikke er fare for at vannet fryser). Dersom du har behov for mer varmtvann enn varmepumpen kan varme opp i løpet av en periode, trykk på felt nr. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC PAWDHWM120ZNT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC PAWDHWM120ZNT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.