User manual PULSAR Y735

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PULSAR Y735. We hope that this PULSAR Y735 user guide will be useful to you.


PULSAR Y735 : Download the complete user guide (303 Ko)

Manual abstract: user guide PULSAR Y735

Detailed instructions for use are in the User's Guide.

[. . . ] Y735) INSTRUCTIONS 8-97 NPED16 Printed in Hong Kong FEATURES q Time/calendar · Dual calendar display · Changeover between 12- and 24-hour indications q 24-hour stopwatch q Regular alarm q Illuminating light (Electroluminescent panel) TIME/CALENDAR MODE Hourly time signal mark AM/PM mark Day indicator Alarm mark C A D SHOWING THE CALENDAR DISPLAY DISPLAY AND MODE CHANGE A With each press, the mode changes as follows: TIME/CALENDAR mode STOPWATCH mode Month Date C C Press and hold to show CALENDAR display. CHANGEOVER OF THE PLACES OF MONTH AND DATE A A Press With each press of D while keeping C pressed, the month and date change places with each other. C C D Date Month A for 2 seconds. Month Date D TIME/CALENDAR SETTING mode ALARM SETTING mode CHANGEOVER BETWEEN 12- AND 24-HOUR INDICATIONS A A With each press of A while keeping D pressed, the time is displayed in the 12-hour and 24-hour indications alternately. * When button A is pressed in the ALARM SETTING mode after operating button C or D to set the alarm time, the mode directly changes to the TIME/CALENDAR and not to the TIME/ CALENDAR SETTING. A [12-hour indication] D A [24-hour indication] D ILLUMINATING LIGHT (Electroluminescent panel) B B Press in any mode. * The light evenly illuminates the display for 4 seconds. q Changeover between 12- and 24-hour indications can also be made by pressing button A while keeping button C pressed. [12-hour indication] [24-hour indication] SHOWING THE DESIGNATED ALARM TIME q While the illuminating light is used, the watch will give out a slight noise. q The electroluminescent panel loses its luminance as the battery voltage gets lowered. q When the illuminating light becomes dim, replace the battery with a new one. [. . . ] q Please note, if button D is pressed in the STOPWATCH mode to stop the alarm ringing, the alarm is stopped but the stopwatch operation is also made. q Alarm test: The alarm can be tested by pressing and holding buttons C and D at the same time in the TIME/CALENDAR mode. The display will return to the TIME/CALENDAR as the buttons are released. TIME/CALENDAR SETTING MODE A Press to show TIME/CALENDAR SETTING mode. TIME/CALENDAR SETTING indicator C A D V Selection of the digits Seconds ¿ Minutes ¿ Hour ¿ Month ¿ Date ¿ Day ¿ q When setting the seconds, press button D in accordance with a time signal. q In second setting, when the seconds count any number from "30" to "59" and button D is pressed, one minute is added and the seconds are reset to "00". q When setting the hour digits in the 12-hour indication, be sure to check that AM/ PM is correctly set. v A v v C Start 5 bar WR Split / Split release 10/15/20 bar WR v D C v D D Reset Finish time of 1st competitor 2nd competitor finishes Finish time of 2nd competitor q q q q q Restart and stop of the stopwatch can be repeated by pressing button C. Measurement and release of split time can be repeated by pressing button D. When button C or D is pressed, a beep sounds to confirm the stopwatch operation. The 1/100 second indicator flashes during the first 40 minutes of measurement. While the split time is measured and displayed, the split indicator flashes. q Even if the STOPWATCH mode is changed to another while the measurement is in progress, it continues counting properly. q When measuring a long period of time, return the STOPWATCH to the TIME/ CALENDAR mode after the stopwatch starts, to prevent any possible mistaken operation. * Pressure in bar is a test pressure and should not be considered as corresponding to actual diving depth since swimming movement tends to increase the pressure at a given depth. ** We recommend that you wear a PULSAR Diver's Watch for scuba diving. TEMPERATURES +50°C -5°C Your watch works with stable accuracy within a temperature range of 5° C and 35° C (41° F and 95° F). Temperatures over 50° C (122° F) or below ­5° C (+23° F) may cause a slight time loss or gain or battery leakage or shorten the battery life. However, the above conditions will be corrected when the watch returns to normal temperature. CHEMICALS MAGNETISM The watch will not be affected by magnetism. N S BATTERY CHANGE 5 Years Battery life : Approx. 5 years Battery : SEIKO CR2016 Be careful not to expose the watch to solvents, mercury, cosmetic spray, detergents, adhesives or paints. may become discolored, deteriorated or damaged. SHOCKS & VIBRATION Light activities will not affect your watch, but be careful not to drop your watch or hit it against hard surfaces, as this may cause damage. PERIODIC CHECK It is recommended that the watch be checked once every 2 to 3 years. [. . . ] Please contact your AUTHORIZED PULSAR DEALER or SERVICE CENTER if you wish to have a new panel fitted (guaranteed one year). STATIC ELECTRICITY CAUTION q The battery is not rechargeable. Never attempt to recharge it, as this may cause battery leakage or damage to the battery. The IC (Integrated Circuit) used in your watch will be affected by static electricity which may disturb the display. Keep the watch away from close contact with objects such as TV screens which emit strong static electricity. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PULSAR Y735




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PULSAR Y735 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.