User manual QSC AUDIO MD POWERED

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual QSC AUDIO MD POWERED. We hope that this QSC AUDIO MD POWERED user guide will be useful to you.


QSC AUDIO MD POWERED : Download the complete user guide (1413 Ko)

Manual abstract: user guide QSC AUDIO MD POWERED

Detailed instructions for use are in the User's Guide.

[. . . ] 1675 MacArthur Blvd. , Costa Mesa, CA, 92626 USA Main Number (714) 754-6175 or toll free (USA only) (800) 854-4079 Customer Service(714) 957-7150 or toll free (USA only) (800) 772-2834 MD Series Powered Loudspeaker Products User Manual MD-FP122/64r MD-FP122/66 MD-FP122/94r MD-FP122/96r MD-FP122/124r MD-FP152/64r MD-FP152/66 MD-FP152/94r MD-FP152/96r MD-FP152/124r 60° x40° (HxV) 60° x 60° 90° x40° 90° x 60° 120° x40° 60° x40° 60° x 60° 90° x40° 90° x 60° 120° x40° 12-inch, two-way 12-inch, two-way 12-inch, two-way 12-inch, two-way 12-inch, two-way 15-inch, two-way 15-inch, two-way 15-inch, two-way 15-inch, two-way 15-inch, two-way *TD-000186-00* TD-000186-00-D Important Safety Precautions & Explanation of Symbols Install in accordance with QSC Audio Product's instructions and under the supervision of a licensed Professional Engineer. WARNING! CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER. The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous" voltage within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in this manual. 5- WARNING: To prevent fire or electric shock, do not expose this equipment to rain or moisture. [. . . ] These connectors are wired in parallel, enabling connection of multiple enclosures in a "daisy-chain" fashion. Balanced connections are recommended for less AC hum and interference, especially with long cable runs. The signal's source impedance should be less than 600 ohms. Input connection Insert the male XLR input into the jack marked IN. Balanced inputs: Connect to the plug as shown. 1= shield (ground) 3= minus (-) 2= plus (+) Input (IN) and Output (OUT) Connectors Unbalanced inputs: Connect to the plug as shown. If the green SIG LED remains on, the amp may need servicing. LIM (Limiter) Indicator LED The red LIM indicator alerts the user to several abnormal conditions within the MD loudspeaker: LIM (limiter) indicator LED Continuous Bright Red Light · Indicates protective mute mode. · The speaker normally passes through muting for several seconds after applying power, after which the light should go out, and sound should be heard. · If the speaker enters Mute during operation, it has either overheated or developed a fault. · Overheating should correct itself within 1-2 minutes, after which sound should resume. In this case AC power should be removed and the speaker serviced. Momentary Bright Red Flashes · During operation, bright flashing indicates clipping (overdrive distortion). · This is normally due to excessive volume, and will likely be accompanied by audible distortion. · If the speaker mutes repeatedly during peaks, there may be a component fault. AC power should be removed and the speaker serviced. Continuous Half-bright Light · Indicates that the internal limiter is reducing gain, due to prolonged clipping and/or excessive temperature. · After several seconds of severe clipping, the limiter will reduce power to protect the speaker and improve the sound. Any further clipping will still result in bright flashes on top of the steady half-bright indication. When the program level is reduced, the limiter will clear after several seconds, and the red indicator will go out. · If the power module overheats, the first response is to trigger limiting, to reduce volume and limit further temperature rise. This results in a steady half-bright illumination that does not clear even after reducing program level. It may take several minutes for temperature to drop and clear the limiter. During this time, the exposed heat sink will feel uncomfortably hot to the touch. If overheating continues, the amplifier will ultimately mute, resulting in a full-bright red indication. When muting clears, the amplifier will resume operation, with thermal limiting still active until it further cools off. · Overheating is usually caused by excessive ambient temperature, since the internal temperature rise of the Class-D power module is relatively low. [. . . ] Operating Voltages AC Power Requirements XLR male, wired in parallel with Input connector Rotatable horn assembly, Gain control, 100 Hz high-pass filter switch, Clip/Limit (red LED), Signal presence (green LED), AC Power (blue LED), all models Thermal limiting, On/Off muting, AC in-rush current limiting, FCC class B (conducted and radiated), UL/CE listed Available in 120V or 230V versions (+15%, -40%) Pink noise (6 dB crest factor) - Idle <0. 5 A (<100 BTU waste heat) / 1/8 power 2. 5 A (570 BTU waste heat) / 1/3 power 5. 0 A (1380 BTU waste heat), full power 15. 0 A (4010 BTU waste heat) Typical program material at full power- 2. 5 A (570 BTU waste heat) AC Power Connector Dimensions Factory supplied cordset: Neutrik Powercon on 10' (3m) #18AWG 120V North American cordset 20. 5" (521mm) W, 35. 0" (889mm) H, 17. 1" (432mm) D, including rear heatsink fins Allow for 100mm (4. 0") of free space behind the enclosure to assure proper amplifier cooling 88 lb/40 kg, all models All models- wear resistant textured paint finish with powder-coated perforated steel grill Weight Finish and Grill Notes: 1- Maximum Peak SPL: Calculated by adding the loudspeaker's sensitivity (1W at 1m) to the peak power (dBw) of the amplifier provided. 2- Coverage: Included angle between -6dB points, plus X, minus Y dB, 500 to 3. 2k Hz, taken at ISO preferred one-third octave intervals, or for an otherwise specified frequency range. 3- Directivity Index (DI): Difference between on-axis SPL and average SPL (considering all axes) for the specified coverage range. DI= 10 log Q 4- Directivity Factor (Q): Directivity index expressed as a power ratio Q=10 exp DI/10 5- Amplifier Power: The maximum sustained power at less than 1% clipping, averaged over the intended frequency range, 6- Input Sensitivity: The sine-wave input voltage required to reach amplifier clipping, measured within the frequency range used to determine Maximum Peak SPL, with the gain on "normal" and no gain reduction due to limiting. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE QSC AUDIO MD POWERED




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual QSC AUDIO MD POWERED will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.