If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SAUNIER DUVAL ENVIROPLUS F28E SB. We hope that this SAUNIER DUVAL ENVIROPLUS F28E SB user guide will be useful to you.
Manual abstract: user guide SAUNIER DUVAL ENVIROPLUS F28E SB04-04
Detailed instructions for use are in the User's Guide.
[. . . ] 2000225294A. 04. 04
Instructions for Use Installation and Servicing
To b e l e f t w i t h t h e u s e r
G. C. 47-920-39 HIGH EFFICIENCY CONDENSING COMBINATION BOILER
F28e
F28e SB
G. C. 41-920-37 HIGH EFFICIENCY CONDENSING SYSTEM BOILER
Saunier Duval, Nottingham Road, Belper, Derbyshire. DE56 1JT
www. saunier-duval. co. uk
11915
F24e
Guarantee Registration
Thank you for installing a new Saunier Duval appliance in your home. [. . . ] Then cut to length, cutting square and removing any burrs.
FLUE ELBOW
8. 3 Standard Side Flue
Fit the flue spigot 'H', supplied with the boiler with the three securing screws to the top of the boiler. Fit the flue elbow 'G' to the flue spigot a small amount of lubricant should be applied to the seal before fitting the flue elbow, see the relevant part of diagram 8. 6. Measure from the outside wall face to the flue elbow 'Y' add 45mm. Make sure that the flue duct groove is engaged on air duct tab and is pushed fully into the air duct. When fully engaged the measurment at the end of the terminal will be 65mm. Then cut, cutting square and removing any burrs, see diagram 8. 5.
LIP SEALS 'Y'
45
8. 4 Side Flue With Extensions
Fit the flue spigot 'H', supplied with the boiler with the three securing screws to the top of the boiler. Fit the flue elbow 'G' to the flue spigot a small amount of lubricant should be applied to the seal before fitting the flue elbow, see the relevant part of diagram 8. 6. Measure from the outside wall face to the flue elbow 'Y' add 45mm. Make sure that the flue duct groove is engaged on air duct tab and is pushed fully into the air duct. When fully engaged the measurment at the end of the terminal will be 65mm. Then cut, cutting square and removing any burrs, see diagram 8. 5.
OUTSIDE WALL FACE
BOILER
65
'Y'+45
CUT
AIR DUCT
AIR DUCT AND FLUE DUCT CUT TO LENGTH
FLUE DUCT
11904
X + 240 ( AIR DUCT ASSEMBLY)
FLUE ASSEMBLY FITTED TO BOILER
X
BOILER MOUNTING WALL
BOILER
OUTSIDE WALL FACE
X + 305 ( FLUE DUCT )
SPACER PIECE
SIDE DUCT - STANDARD / EXTENDED FLUE Diagram 8. 4 Diagram 8. 5
REAR FLUE
2000225294A
24
12257
8. 2 Rear Flue
8 Horizontal Top Flue Preparation and Fitting
8. 5 Flue Assembly
The flue assembly is an entirely push fit design. The lip seals should be fitted in the correct orientation into the flue elbow, see diagram 8. 4. Having cut the air and flue ducts as described in sections 8. 1 - 8. 4, assemble the flue as follows: the flue can be assembled externally and internally by following sections A and C, or entirely from inside by following sections B and C. NOTE: Ensure that the 'up' label on air pipe 'B' is at the top, i. e. the tab protruding into the hole at the outer end of the pipe is uppermost. For internal fitting it may be necessary to mark the flue protruding internally 'top', to ensure the flue does not twist on fitting. Internal fitting - Fit the rubber sealing collar 'D' into the groove at the outer end of the air pipe 'B'. Fit spacer piece 'E' over air pipe 'B', ensure correct orientation, see diagram 8. 5. Push the air pipe 'B' through the wall until collar 'D' is clear of the outside face of the wall. Pull the air pipe 'B' back to ensure that collar 'D' is pulled up to the outside wall face. Ensure spacer piece 'E' is pushed into the wall, see diagram 8. 4. Fit sealing flange 'F' over the air pipe but not against the inside wall face. [. . . ] Unthread the retaining cord and remove the control box by drawing it outwards away from its retaining slots, see relevant part of diagram 11. 1.
SECURING SCREWS (2)
THREE WAY VALVE PCB
(F24e/F28e ONLY)
16. 33 Fuses PCB - Control Box
Remove the front casing, refer to the relevant part of section 16. 1. Drop down the control panel and undo three screws securing the rear cover and lift up, see relevant part of diagram 11. 1. Remove the fuse holder from the mainPCB and replace fuse, see diagram 16. 22.
PCB - Transformer
For access, refer to section 16. 1. Replace fuse.
16. 34 230V Controls Option
For access, refer to section 16. 1. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SAUNIER DUVAL ENVIROPLUS F28E SB
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SAUNIER DUVAL ENVIROPLUS F28E SB will begin.