User manual SCOTSMAN NM1852

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SCOTSMAN NM1852. We hope that this SCOTSMAN NM1852 user guide will be useful to you.


SCOTSMAN NM1852 : Download the complete user guide (820 Ko)

Manual abstract: user guide SCOTSMAN NM1852

Detailed instructions for use are in the User's Guide.

[. . . ] NM1852 INTRODUCTION To the owner or user: The service manual you are reading is intended to provide you, and the maintenance or service technician, with the information needed to install, start up, clean, maintain, and service this ice system. The NM1852 is a modular ice system that fits a variety of Scotsman ice storage bins. It features: front service for the freezer, gearmotor, control box, water reservoir, and bin control; an electronic circuit for monitoring ice and water level; a thermostatic expansion valve; and R-22 as the refrigerant. TABLE OF CONTENTS Installation For the Installer Specifications . 16 Service Diagnosis Removal and Replacement Reservoir and Bin Controls . [. . . ] For more information on removal of these parts, see REMOVAL AND REPLACEMENT. Remove 3 hex studs holding ice chute cover to ice chute, and remove cover. Loosen band clamp under ice chute, and remove ice chute from evaporator. Drain the evaporator by pulling down and uncapping the evaporator drain tube. ALLEN SCREWS BREAKER & BEARING & AUGER ASSEMBLY 7. After the auger has been removed, allow the auger to dry: if the auger is not bright and shiny, it must be cleaned. Reverse to reassemble. August 1993 Page 19 NM1852 SERVICE DIAGNOSIS: Condition - No Ice Being Produced STATUS: NOTHING OPERATES A. Check: The 3 reset switches, (spout switch, high and low pressure): depress and release each switch. If the still does not start, check: the spout switch; the high and the low side pressures. Check the low pressure cut out, if closed, go to E; if it is open, it could be due to: · Low refrigerant charge · The auger not turning · Restricted system · TXV not opening 1. Check the low side pressure, the low pressure cut out opens at pressure below 4 psig. Check if the auger is turning, if it is not, remove the gearbox and: Check for internal damage, repair and replace in the machine. Check for low charge, add some refrigerant, if the unit will operate, (normal low side pressure being about 25 psig) stop and look for a leak, recover, repair, replace the drier, evacuate, and weigh in the nameplate charge. If, with added charge, the unit does not operate: Check for a restricted system, replace the drier, evacuate, and weigh in a nameplate charge. Check for a Thermostatic Expansion Valve that does not open, if defective, replace it. Check the high pressure cut out, if closed, go to F; if open check: 1. Check the high side pressure, reset the control, and observe: on water cooled, that water soon begins to flow from the condenser drain; or, on air cooled, that the fan is forcing air through the condenser. If the unit trips out on pressures below 400 psig, replace the control. If the pressures rise above the trip out point, and the unit shuts down: a. Check for adequate water flow on water cooled, if adequate, clean the interior of the condenser. If the pressures are still too high replace the water regulating valve. If the air flow is poor because of the installation, advise the user that the unit should be moved, or the air around it kept cooler. Check that the fan blades are clean, and the fan secure to the fan motor shaft. [. . . ] To use them, remove the cap from the valve ports and the cap from the top of the valve body. Attach gauge manifold and then use a 3/16" allen wrench to loosen the valve. Although pressure readings may be taken with the valve cracked open, several turns are required to completely open the valve. Close the valve and replace the caps when the job is finished. ALLEN WRENCH Torque Stem to 6-8 ft. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SCOTSMAN NM1852




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SCOTSMAN NM1852 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.