User manual SHARP AF-A07CE/A09CE/A12CE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP AF-A07CE/A09CE/A12CE. We hope that this SHARP AF-A07CE/A09CE/A12CE user guide will be useful to you.


SHARP AF-A07CE/A09CE/A12CE : Download the complete user guide (884 Ko)

Manual abstract: user guide SHARP AF-A07CE/A09CE/A12CE

Detailed instructions for use are in the User's Guide.

[. . . ] The air conditioner should be installed with a strong external support to minimize noise and vibration, and for the purpose of safe installation, repair, replacement and secure positioning. Avoid installing the air conditioner where it is exposed to direct sunlight. AF-A07CE, AF-A09CE AF-A12CE 36. 0~37. 0 cm (14. 2"~14. 6") 48 9. 0 . 0~4 "~19 cm 38. 5~39. 5 cm (15. 2"~15. 6") More than 20 cm(8") 57. 0 (22. 4 ~58 m . 0 c More than 20 cm(8") More than 20 cm (8") (18. 9 . 3") More than 20 cm (8") "~22 . 8") 8~20 cm(3"~8") 8~20 cm(3"~8") More than 40cm(16") Air outlet Air inlet More than 20cm(8") More than 40cm (16") Air inlet More than 20cm(8") Air outlet Air inlet Air inlet About 1cm (3/8") POWER CABLING GROUNDING WARNING : THIS APPLIANCE MUST BE GROUNDED. Fit a disconnect switch, having a contact separation of at least 3mm in all poles, to the electricity power line. [. . . ] (Fig. 13) Crank shaft OPERATION INSTRUCTIONS OPERATION INSTRUCTIONS PRECAUTIONS POWER CORD REPLACEMENT WARNING: For replacement, use only the manufacturer specified power cord. Replacemant should be conducted by a qualified technician or a serviceman. Consult your dealer for detailed information concerning replacement of the power cord. WAIT FOR 3 MINUTES BEFORE RESTARTING THE COOLING OPERATION Whenever you turn the air conditioner OFF, wait for at least three (3) minutes before restarting the unit. If you restart the air conditioner within three minutes, a protective device in the unit may cause the air conditioner to shut off. This protective device will prevent cooling operation for about 5 minutes. IF A POWER FAILURE OCCURS DURING OPERATION, MAKE SURE TO TURN OFF THE AIR CONDITIONER After resumption of power supply, restart the air conditioner . If the power was off for less than three minutes, make sure to wait for at least three minutes before restarting the unit. If the air conditioner is not turned off during a power failure, the resumption of power supply will cause excessive voltage. The air conditioner will be over-loaded and will not operate for about 5 minutes. TO STOP THE UNIT, TURN THE SELECTOR KNOB TO THE "OFF" POSITION. ALWAYS USE A FUSE WITH THE PROPER AMP RATING Never use wire, pins or anything other than the proper fuse. In replacing a blown fuse, or if there is the problem of constant fuse blowing, contact your dealer or our service center. VENTILATE THE ROOM PERIODICALLY DURING USE, ESPECIALLY IF GAS APPLIANCES ARE USED. NOTES ON OPERATION POWER SUPPLY VOLTAGE If the power supplied to the unit is not within plus / minus 10 % of the specified rating, the unit may not function and the fuse may blow. OPERATING TEMPERATURE RANGE INDOOR TEMP. A built-in protective device might prevent the unit from operating when used out of this range. Condensation might form on the air outlet when the unit operates continuously in the COOL mode when the humidity is over 80 percent. NOISE LEVEL As the surrounding environment is comparatively silent at night, noise from the air conditioner may be louder at night than in the day time. If you feel that noise of the air conditioner is too loud, switch the "SELECTOR" knob to the "LOW COOL" position. WATER IN THE BOTTOM TRAY Water will be collected at the bottom tray of the unit. Water condenses on the evaporator coil in the front part of the unit and is channeled to the rear where it is picked up by the condenser fan. The water is blown onto the condensor coil fins, this creates a "splashing" sound which is normal. When the tray is filled up with water, excessive water will be drained outside through a grooved channel in the tray. E-6 MODES OF OPERATION PART NAMES AUTO SWING 4 3 2 1 5 6 7 8 LOW COOL FAN OFF MED COOL HIGH COOL Super Quiet Control panel Auto swing switch Thermostat knob Selector knob Ventilation lever THERMOSTAT 9 10 COOLER SELECTOR WAIT THREE MINUTES BEFORE RESTARTING SELECTOR KNOB Use to select the desired mode. OFF FAN LOW COOL MED COOL HIGH COOL Both the fan and cooling operation are off. [. . . ] Close all windows and doors for maximum cooling effect. LEFT / RIGHT AIR FLOW ADJUSTMENT LOUVERS DO NOT SWING · Is the crank shaft fit properly into the louver link?Make sure to slide the crank shaft into the opening of the louver link at the back of the front panel. The auto swing louver can be activated only at LOW COOL, MED COOL and HIGH COOL settings. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AF-A07CE/A09CE/A12CE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AF-A07CE/A09CE/A12CE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.