User manual SHARP MD-MT877

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP MD-MT877. We hope that this SHARP MD-MT877 user guide will be useful to you.


SHARP MD-MT877 : Download the complete user guide (2463 Ko)

You may also download the following manuals related to this product:

   SHARP MD-MT877 QUICK GUIDE (190 ko)
   SHARP MD-MT877 OPERATION MANUAL (1429 ko)

Manual abstract: user guide SHARP MD-MT877

Detailed instructions for use are in the User's Guide.

[. . . ] S3118MDMT877/ PORTABLE MINIDISC RECORDER MD-MT877(S) MODEL MD-MT877C(S) · In the interests of user-safety the set should be restored to its original condition and only parts identical to those specified be used. CONTENTS Page SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 NAMES OF PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 OPERATION MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · Whenever the DISP button is pressed in the TEST-REC menu, the target address changes as follows. 7. NORMAL Mode · When the STOP button is pressed while the NORMAL menu appears, the mode changes to the TEST mode stop state. · Indication during operation Indication of memory capacity on main unit LCD [ ] + Level meter : Internal mode : Address (Cluster section) : Address (Sector section) · Selection of sound volume, BASS, etc. · If the STOP button is pressed during operation in the NORMAL mode, the NORMAL mode is cancelled, and the power is turned off. 0032 -- 03C0 -- 0700 -- 08A0 --0950 -- 0032 -- When the PLAY button is pressed while a target address is displayed, continuous playback is performed after searching that address. · Whenever the MODE button is pressed in the TEST-REC mode target address is displayed, the digit which is changed by the FAST FORWARD/REVERSE button changes as follows. 0032 -- 0032 -- 0032 -- 0032 -- · When the FAST FORWARD button is pressed in the TEST-REC mode target address is displayed, the digit of address specified by the MODE button is set to +1h. (0 to F) · When the FAST REVERSE button is pressed in the TEST-REC mode target address is displayed, the digit of address specified by the MODE button is set to -1h. (0 to F) * When the FAST FORWARD/REVERSE button is held down, the setting changes continuously, one cycle being 100 ms. · When the VOLUME+/­ button is pressed in the TEST-REC mode or continuous record mode, the laser record power changes. (Servo gain changes also according to record power. ) * After the laser record power is indicated for one second, the ad] dress indication is restored. [ R P W _ · : Address · : Laser power cord · Operation is disabled if the premastered disc or disc is in miseraseprotected state. 8. Error data display Mode · Reversing when FAST REVERSE button is pressed · When the STOP button is pressed while the error data indication menu appears or during error data indication, the mode changes to the TEST mode stop state. · Error which occurred in the TEST mode is also stored in the memory. · When the DISP button is pressed while the error data indication menu appears, the error data is initialized. [CLEAR_] · : Error Code Explanation of error history code 13h : Adjustment servo retraction excessive retrial 16h : C. IN detection time-over 17h : A, B, E, F, and TCRSO offset measurement value out of tolerable range 21h : Focus retraction completion allowable time-over 23h : Track search completion allowable time-over 32h : P-TOC read failure 42h : U-TOC read failure 44h : U-TOC write data write disabled/read check error 45h : U-TOC write test failure 52h : SD write data write disabled 72h : EEPROM data read check sum error 73h : Record head drive disabled (by EJECT lever) 91h : Ambient temperature is higher that the allowable temperature Error messages Can't READ The details ' ' 'f': Focus 'a': Servo adjustment 's': Track such 'r': TOC information reading 'u': UTOC information reading 'w': At the time of data writing 'p': Spindle start Er-MD The details ' ' '41': UTOC light test error '80': EEPROM information reading error ­ 14 ­ MD-MT877/MD-MT877C EEPROM (IC402) writing procedure 1. Procedure to replace EEPROM and write initial value of microcomputer in EEPROM (1) Replace EEPROM. (Refer to page 12 "Entering the TEST mode". ) (4) Version display (At the time of settlement of the test mode by the button operation. ) [Ver. ] EEPROM version (c ~ z) Microcomputer ROM version (5) The whole LCD lights. [ TEST ] (7) Press the "BASS" button, and press 1 time the "FAST REVERSE" button. [ EEPROM ] (8) Perform the operation to display "EEPROM SETTING MODE CHART", compare the EEPROM DATA LIST with the display, and set according to the EEPROM DATA LIST with the VOLUME+ or VOLUME­ button. (Refer to the Temperature reference setting method. ) (10) Set according to the EEPROM DATA LIST. Temperature reference setting method [1] Measurement, calculation and setting procedure (1) Set the TEST mode. · Button operation in order of BASS, FAST REVERSE x 1 time, PLAY, PLAY in the test mode STOP state. [. . . ] 56* 57 58 59 78 79 80 81 Port Name EXPORT4 EXPORT5 EXPORT6 EXPORT7 EXPORT3 EXPORT2 EXPORT0 EXPORT1 Terminal Name Input/Output Undecided justice LDCNT1 LDCNT2 EMPH1 HDON OPTCNT DAPON ADPON Output Output Output Output Output Output Output Output Not used Recording head raising-lowering control output 0. 'H': Record electric current 'H': Circuit operation ON 'H': Operation ON 'H': Operation ON Remarks In this unit, the terminal with asterisk mark (*) is open terminal which is not connected to the outside. *1: List of TEST port settings TEST1 H H L L TEST0 H L H L Details Normal mode No adjustment mode Test mode (Settings prohibited) *2: List of EMPH port settings EMPH1 H H L L EMPH0 H L H L Details fs=32K: 'ON' fs=48K: 'ON' OFF fs=44. 1K: 'ON' *3: List of LDCNT port settings LDCNT2 H H L L LDCNT1 H L H L Brake Drive UP Drive DOWN Output OFF Details ­ 43 ­ MD-MT877/MD-MT877C --MEMO-- ­ 44 ­ MD-MT877/MD-MT877C PARTS GUIDE PORTABLE MINIDISC RECORDER MD-MT877(S) MODEL MD-MT877C(S) "HOW TO ORDER REPLACEMENT PARTS" To have your order filled promptly and correctly, please furnish the following information. For location of SHARP Parts Distributor, Please call Toll-Free; 1-800-BE-SHARP MARK: SPARE PARTS-DELIVERY SECTION Explanation of capacitors/resistors parts codes Capacitors VCC . . . . . . . . . . . . . . . . . . . . . . . Cylindrical type (without lead wire) VC · · MN . . . . . . . . . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP MD-MT877




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP MD-MT877 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.