User manual SHARP MD-M2H OPERATION MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP MD-M2H. We hope that this SHARP MD-M2H user guide will be useful to you.


SHARP MD-M2H OPERATION MANUAL: Download the complete user guide (1224 Ko)

You may also download the following manuals related to this product:

   SHARP MD-M2H (1618 ko)
   SHARP MD-M2H (1589 ko)
   SHARP MD-M2H (1387 ko)
   SHARP MD-M2H (1657 ko)
   SHARP MD-M2H (1636 ko)
   SHARP MD-M2H (1636 ko)
   SHARP MD-M2H (1501 ko)
   SHARP MD-M2H (1446 ko)
   SHARP MD-M2H QUICK GUIDE (174 ko)

Manual abstract: user guide SHARP MD-M2HOPERATION MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] MD MICRO SYSTEM OPERATION MANUAL MODEL MD-M2H Thank you for purchasing this SHARP product. To obtain the best performance from this product, please read this manual carefully. It will guide you in operating your SHARP product. MD-M2H MD micro system consisting of MD-M2H (main unit) and CP-M2H (speaker system). CONTENTS Page SPECIAL NOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Back cover SPECIAL NOTES NOTE FOR USERS IN THE U. K. The mains lead of this product is fitted with a nonrewireable (moulded) plug incorporating a 3A fuse. [. . . ] Note: q If the EON button is pressed when "EON" is not displayed, "NO EON" will appear for 5 seconds to indicate that the unit cannot enter the EON stand-by mode. 1 Tune in the desired RDS station (when a station name is being displayed). Checking the stand-by mode setting: When in the EON stand-by mode, press the EON button. ("TI" "WAITING") 2 Press the EON button when "EON" appears. To cancel the EON stand-by mode: When in the EON stand-by mode, press the EON button. Note: q If neither "TP" nor "TA" appear, then even if "EON" appears the unit cannot enter the EON-TI standby mode. TI) button is pressed after TI is selected, "NO TI" will flash for 4 seconds. q "PTY TI" and "SELECT" will appear alternately for about 6 seconds. 3 Whilst they are being displayed, select the TI (Traffic Information) pressing the PRESET (X or W) button. 4 Within 4 seconds, press the PTY. TI SEARCH button. DISC TOC TRACK MEMORY RANDOM TOTAL REMAIN DISC TOC TRACK MEMORY RANDOM TOTAL REMAIN kHz REC MHz SLEEP q "TI" and "WAITING" will appear for 2 seconds each. q "TI" will appear, and the unit will enter the EONTI stand-by mode. 26 (Continued) About the TP and TA indicators TP indicator Not lit Not lit Lit Lit TA indicator Not lit Lit Not lit Lit Meaning This programme does not carry traffic announcements nor does it refer, via EON, to a programme that does. This programme carries EON information about another programme which gives traffic information. This programme carries traffic announcements but none are being broadcast at present and may also carry EON information about other traffic announcements. A traffic announcement is being broadcast on this programme at present. In the following cases, the EON stand-by mode will be cancelled. q When the unit is switched to another band in the EON stand-by mode q When you change the FM station whilst in the EON stand-by mode q When a preset call is made Notes: q During the same programme as the specified PTY (or TA) is being broadcast on the station you are receiving, the unit will not switch to other network station. q If there are more than two other network stations you want to listen to, compare the strength of each station's signal and tune in the station with the strongest signal. (EON-AF) However, if the frequency of other network station has been stored in the preset channel memory, the unit will switch to that preset channel. q If you want to cancel the reception of an ON (other network) station which was tuned in by the EON system and return to the original station you were receiving, press the EON button. q After the unit returns to the original station, the stand-by mode will still be active. (The "TI" or "PTY" will remain lit. ) q The unit will not switch from the ON station to another network station. q When the unit switches automatically to "other network" station, if there is any problem with this station or the station cannot be received properly "WEAK SIG" will appear and the unit will return to the original station. q Even if the unit switches from the station you are listening to directly to one "other network" station which is in the preset memory, if the signal is very weak, the unit will search for another station of other network and find out the station with the strongest signal and switch to it. However, if the signals from all the other network stations are very weak, or if the tuning conditions are very bad (due to electrical noise), the unit will be displayed "WEAK SIG", and the unit will return to the original station you were receiving. 27 RECORDING s Differences from tape recordings You cannot record music on the reverse side of a MiniDisc. MiniDiscs are single sided and should only be inserted with the correct side up. You don't need to search for the starting point at which to record. You can check the total or remaining recordable time (possible recording) before recording. This lets you plan a recording session so that the last song will not come to an abrupt end before it has finished. CD First track Track A Second track Track B Second track Track B Third track Track C MD First track Area for TOC (recording track numbers, track names, etc. ) Area for recording the sound Third track Track C Track A s Disc writing (TOC) The TOC (Table of Contents) is information on track numbers and recording areas to allow the unit to recognize musical selections or sounds. The entire MD is controlled depending on this TOC, which enables the unit to find the beginning of a track quickly or to automatically record in a vacant area. [. . . ] q Do not use chemically treated cleaning cloths or other chemicals. 1 Press the ON/STAND-BY button to enter the stand-by mode. s Care of compact discs 2 Press the ON/STAND-BY button whilst holding down the EQUALIZER button and the PLAY button. Caution: q The operation explained above will erase all data stored in memory including clock and timer settings, and tuner, MD and CD presets. NO YES Correct Compact discs are fairly resistant to damage, however mistracking can occur due to an accumulation of dirt on the disc surface. Follow the guidelines below for maximum enjoyment from your CD collection and player. q Do not write on either side of the disc, particularly the non-label side. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP MD-M2H




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP MD-M2H will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.