User manual SHARP PG-F255W

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP PG-F255W. We hope that this SHARP PG-F255W user guide will be useful to you.


SHARP PG-F255W : Download the complete user guide (1024 Ko)

You may also download the following manuals related to this product:

   SHARP PG-F255W (8635 ko)
   SHARP PG-F255W (3482 ko)
   SHARP PG-F255W DATASHEET (497 ko)
   SHARP PG-F255W (3861 ko)
   SHARP PG-F255W (3684 ko)
   SHARP PG-F255W annexe 1 (3684 ko)
   SHARP PG-F255W ANNEXE 4 (636 ko)
   SHARP PG-F255W SETUP MANUAL (1199 ko)

Manual abstract: user guide SHARP PG-F255W

Detailed instructions for use are in the User's Guide.

[. . . ] DATA PROJECTOR MODEL PG-F255W SETUP MANUAL Connecting Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 RS-232C Baud Rate Setting ([6]RS-232C Baud Rate) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Disconnecting All Connections ([D]Disconnect All) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Entering ADVANCED SETUP MENU ([A]Advanced Setup) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] e. g. 1 : 192. 168. 150. 253 e. g. 2 : smtp123. sharp. co. jp * When using a domain name, make settings for the DNS server. The name set here appears in the "Originator Name" column of the body of the message. Originator E-mail Address Originator Name Data Port Search Port Note · SMTP Server, Originator E-mail Address and Originator Name can be up to 64 characters. · You can input the characters below: SMTP Server and Originator E-mail Address : a-z, A-Z, 0-9, !, #, $, %, &, *, +, -, /, =, ?, ^, {, |, }, ~, _, ', . , @, ` (You can input "@" only one time for "Originator E-mail Address". ) Originator Name : a-z, A-Z, 0-9, -, _, (, ), space · If the settings of "3. Setting up a Network Connection for the Projector" on pages 13 and 14 are incorrectly set, e-mail will not be send. After clicking the "Apply" button, the set values appear. Confirm that the values are set properly, and then click the "Confirm" button. Note · After setting items, wait for about 15 seconds and then re-access. · You can input the characters below : A-Z, 0-9, -, _, (, ), space (When "a-z" are input, they are converted to "A-Z" automatically. ) -18 Controlling the Projector via LAN Setting Error Items and Destination Addresses to which E-mail is to be Sent when an Error Occurs (Mail ­ Recipient Settings) Setting Error Items and the URL that are to be Displayed when an Error Occurs (Service & Support ­ Access URL) On this screen, you can input e-mail destinations to which error notification (error items) e-mails are sent. Items E-mail Address Description Set addresses to which error notification e-mail is sent. Error Mail Error e-mail is sent on the error (Lamp, Temp, items checked in their check Fan, Cover) boxes. This allows you to confirm that the settings for e-mail transmission are properly set. On this screen, you can make settings of the URL and error items that are to be displayed when the projector has generated an error. Items Access URL Description Set the URL that is to be displayed when an error occurs. Condition The URL is displayed when an (Always, Lamp, error checked in their check Temp, Fan, Cover) boxes occurs. This allows you to confirm that the URL site is properly displayed. Note · E-mail Address can be up to 64 characters. · You can input the characters below : a-z, A-Z, 0-9, !, #, $, %, &, *, +, -, /, =, ?, ^, {, |, }, ~, _, ', . , @, ` (You can input "@" only one time. ) · For details about error items, refer to the projector's operation manual. Example of the display when an error occurs -19 Setting up the Projector Using RS-232C or Telnet Connect the projector to a computer using RS-232C or Telnet, and open the SETUP MENU on the computer to carry out various settings for the projector. When Connecting Using RS-232C 7 Input "setup" and press the "Enter" key. · SETUP MENU will be displayed. 1 2 Launch general purpose terminal emulator. Input settings for the RS-232C port of the terminal emulator as follows. Baud Rate Data Length Parity Bit Stop Bit Flow Control : 9600 bps* : 8 bit : None : 1 bit : None SETUP MENU ---------------------------------SETUP MENU-------------------------------[1]IP Address [2]Subnet Mask [3]Default Gateway [4]User Name [5]Password [6]RS-232C Baud Rate [7]Projector Name [8]DHCP Client [A]Advanced Setup [D]Disconnect All [V]View All Setting [S]Save & Quit [Q]Quit Unchanged setup> Note · User name and password are not set in the factory default settings. · If the user name or password is entered incorrectly three times, SETUP MENU will be quit. * This is the factory default setting. If the value of Baud Rate for the projector has been changed, set Baud Rate here according to the changed value on the projector. 3 4 5 Input "PJS11234" and press the "Enter" key. Input "PJS25678" and press the "Enter" key within 10 seconds. Input the user name and press the "Enter" key. · If a user name has not yet been set, just press the "Enter" key. 6 "Password:" is displayed. Input the password and press the "Enter" key. · If a password has not yet been set, just press the "Enter" key. -20 Setting up the Projector Using RS-232C or Telnet SETUP MENU When Connecting Using Telnet ---------------------------------SETUP MENU-------------------------------[1]IP Address [2]Subnet Mask [3]Default Gateway [4]User Name [5]Password [6]RS-232C Baud Rate [7]Projector Name [8]DHCP Client [A]Advanced Setup [D]Disconnect All [V]View All Setting [S]Save & Quit [Q]Quit Unchanged setup> 1 2 3 4 Click "Start" from the Windows® desktop and select "Run". (If the IP address of the projector is 192. 168. 150. 2. ) Click the "OK" button. Note · If the IP address has been changed, be sure to enter the new IP address in step 2. · User name and password are not set in the factory default settings. · If the user name or password is entered incorrectly three times in steps 4 or 5, SETUP MENU will be quit. "User Name:" is displayed. Input the user name and press the "Enter" key. · If a user name has not yet been set, just press the "Enter" key. 5 "Password:" is displayed. Input the password and press the "Enter" key. · If a password has not yet been set, just press the "Enter" key. 6 Input "setup" and press the "Enter" key. · SETUP MENU will be displayed. -21 Setting up the Projector Using RS-232C or Telnet SETUP MENU SETUP MENU (Main Menu) ADVANCED SETUP MENU ADVANCED SETUP MENU ******************** ADVANCED SETUP MENU *********************** [1]Auto Logout Time [2]Data Port [5]Network Ping Test [6]Accept IP Addr(1) [7]Accept IP Addr(2) [8]Accept IP Addr(3) [9]Accept All IP Addr [0]Search Port ---------------------------------SETUP MENU-------------------------------[1]IP Address [2]Subnet Mask [3]Default Gateway [4]User Name [5]Password [6]RS-232C Baud Rate [7]Projector Name [8]DHCP Client [A]Advanced Setup [D]Disconnect All [V]View All Setting [S]Save & Quit [Q]Quit Unchanged setup> [!]Restore Default Setting [Q]Return to Main Menu [1]IP Address IP address settings. [. . . ] (Example) When the IP address is "192. 168. 150. 2" and the subnet mask is "255. 255. 255. 0" for the projector, the IP address for the computer should be "192. 168. 150. X" (X=3-254) and the subnet mask should be "255. 255. 255. 0". · Gateway When the gateway setting for the projector is "0. 0. 0. 0" (Not Used), or the gateway setting for the projector and the default gateway setting for the computer are the same: · The subnets for the projector and the computer should be the same. · The IP address parts shown by the subnet mask for the projector and the computer should be the same. (Example) When the IP address is "192. 168. 150. 2" and the subnet mask is "255. 255. 255. 0" for the projector, the IP address for the computer should be "192. 168. 150. X" (X=3-254) and the subnet mask should be "255. 255. 255. 0". Note · When "DHCP Client" is set to "OFF" on the projector IP address : 192. 168. 150. 2 Subnet mask : 255. 255. 255. 0 Gateway address : 0. 0. 0. 0 (Not Used) · For network settings for the projector, refer to page 13. -32 Troubleshooting \ Take the following steps for checking the network settings for the computer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP PG-F255W




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP PG-F255W will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.