User manual SIEMENS ILE-61

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SIEMENS ILE-61. We hope that this SIEMENS ILE-61 user guide will be useful to you.


SIEMENS ILE-61 : Download the complete user guide (749 Ko)

Manual abstract: user guide SIEMENS ILE-61

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual May 2008 milltronics ILE-61 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel: This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. [. . . ] Tighten the right taper pin nut to lock the sensing plate shaft in place. Tighten the left taper pin nut. shaft socket flat side up taper pin (flat side down) Page 4 Milltronics ILE-61 ­ INSTRUCTION MANUAL 7ML19985CX01 Viscous Damper 1. If necessary, top up the damper (to near overflowing) with the damping fluid supplied. Store the damper cover shipping screws, remaining damper fluid, and filler bottle for future use. Note: The damper must be full and free of air bubbles with the damper cover in the UP position during flowmeter operation. filler bottle filler plug shipping screws damper cover Interconnection Non-Hazardous Unit without LVDT Conditioner Card * See note below for Encapsulated (Hazardous-rated) LVDT color codes. to LVDT G R N B L K Y E L B L U R E D flowmeter terminal block cable clamp S I G ­ C O M E X C E X C + to integrator (LVDT connection) ­ ­ *For Encapsulated LVDT (hazardous) YEL = WHITE BLU = ORANGE GRN = YELLOW Note: Ground shield at Integrator only. 7ML19985CX01 Milltronics ILE-61 ­ INSTRUCTION MANUAL Page 5 Non-Hazardous Unit with Sensing Head Mounted LVDT Conditioner Card · · Not applicable to Hazardous-rated units LVDT to LVDT Conditioner Card connections are made by Milltronics LVDT Milltronics LVDT Conditioner Card LVDT INTEGRATOR S I G / C O M E X C + E X C - C C. Run cable shields through SHLD terminals and ground at Integrator only. Ensure that connection between TB 2 and TB 17 is made. 7ML19985CX01 Milltronics ILE-61 ­ INSTRUCTION MANUAL Page 7 Calibration General A test weight is a calibration reference used to simulate a material impact force (test rate) on the flowmeter sensing plate during the integrator span calibration. The test weight is also used to perform a test to verify that the flowmeter sensing head is level. Test Rate (TPH) = Test Weight (grams) 45* grams/ TPH Alternatively, to determine the test weight required for a specific test rate: Test Weight (grams) = 45* grams x Test Rate (in TPH) 1 TPH *Use 60 grams for A-300 flowmeters. = 155 TPH Test Rate = 7000 grams 45 grams/TPH Note: Use metric tons per hour (t/h) or short tons per hour (STPH) as applicable for TPH. LVDT Output Zero Adjustment 1. Connect a voltmeter across the LVDT green and yellow (or yellow and white) wires. With no load applied to the sensing plate, observe 0. 10 V AC on the voltmeter. Note: If the LVDT output is 0. 10 to 0. 05 V AC, skip to span test, otherwise, proceed as follows: a. Loosen the locknut on the LVDT threaded core. b. Turn the core in/out of the LVDT until 0. 10 to 0. 05 V AC is obtained. c. Tighten the locknut, ensuring the measured value is maintained. LVDT core moving beam locknut LVDT ± 0. 05 V AC >± 0. 05 V AC to integrator LVDT EXC. or LVDT conditioner card increase decrease Page 8 Milltronics ILE-61 ­ INSTRUCTION MANUAL 7ML19985CX01 Span Test 1. The LVDT output should increase steadily until a level of 0. 75 to 1. 0 V AC is achieved. The LVDT output should decrease steadily until zero is reached and then increase to 0. 25 to 0. 50 V AC. Ensure the LVDT output always returns to 0. 10 to 0. 05 V AC, (on the right hand side of zero), when pressure on the moving beam is released. Note: The LVDT core must not contact the inside of the LVDT over the range of core travel. The actual LVDT core travel during this procedure is less than 3 mm (1/8"). 0. 750 to 1. 000 0. 050 to 0. 150 0. 015 to 0. 500 Sensing Head Level Test 1. With the voltmeter still connected to the LVDT output, hang the test weight directly off the sensing plate. Observe the display value does not change by more than 0. 01 V AC. Note: If the change is greater than 0. 01 V AC, adjust the sensing head level until the change with and without the test weight on the sensing plate is less than 0. 01 V AC. [. . . ] Milltronics ILE-61 ­ INSTRUCTION MANUAL Page 13 7ML19985CX01 Troubleshooting Every Millltronics ILE-61 sensing head is subjected to extensive quality assurance procedures to ensure the highest degree of quality, reliability, and performance is achieved. The following listing indicates the probable cause, and proper course of action to be taken should the specified fault symptom occur. Symptom Cause Action Refer to Installation\Integrator LVDT Interconnection Refer to Installation/ Viscous Damper Program and Calibrate the integrator Refer to Range Springs Wrong or bad integrator connection Integrator Rate display Viscous damper lid in shipdoesn't change when sensing ping position plate is moved Integrator not prepared for operation Span adjustment does not have enough range Range spring not suited to application Sensing head not level Refer to Installation and Calibration/Sensing Head Level Test Moving beam is mechanically Ensure moving beam does not limited hit travel stops between -20 % Measurement results are not and 150 % flowrates repeatable Leaf springs are damaged Replace leaf springs, recalibrate flowmeter, and integrator Material flow patterns vary Consult Siemens Milltronics or your distributor Accuracy varies with material flowrate Non-linear operation Refer to Linearity Page 14 Milltronics ILE-61 ­ INSTRUCTION MANUAL 7ML19985CX01 Linearity To test linearity, at least 3 test weights are used. Record the integrator rate display value associated with each test weight applied to the flowmeter. If all the recorded display values are accurate, the flowmeter measurement is linear. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIEMENS ILE-61




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SIEMENS ILE-61 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.