User manual SIEMENS RDD10

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SIEMENS RDD10. We hope that this SIEMENS RDD10 user guide will be useful to you.


SIEMENS RDD10 : Download the complete user guide (337 Ko)

Manual abstract: user guide SIEMENS RDD10

Detailed instructions for use are in the User's Guide.

[. . . ] 3 031 Room Temperature Controllers with LCD for heating systems RDD10. . . 2-position control with ON / OFF output for heating Operating modes: normal operation and energy saving mode Automatic operating mode change over as an option Mains-powered AC 230 V (RDD10) or battery-powered DC 3 V (RDD10. 1) Use The RDD10. . . Typical applications: · Apartments · Commercial spaces · Schools For the control of the following pieces of equipment: · · · · Thermic valves or zone valves Gas or oil burners Fans Pumps CE1N3031en 24. 09. 2003 Siemens Building Technologies HVAC Products Functions The controller acquires the room temperature with its integrated sensor and maintains the setpoint by delivering control commands. [. . . ] This Display Display in normal operation Display in energy saving mode 2/8 Siemens Building Technologies HVAC Products Room temperature controllers CE1N3031en 24. 09. 2003 Type summary Type reference RDD10 RDD10. 1 Features Mains-powered AC 230 V Battery-powered DC 3 V Ordering When ordering, please give name and type references, e. g. Valve actuators are to be ordered as separate items. Equipment combinations Type of unit Motoric on/off actuator Thermal actuator (for radiator valve) Thermal actuator (for small valve 2, 5 mm) Accessories Type reference SFA21. . . . Description Adapter plate 120 x 120 mm for 4" x 4" conduit boxes Adapter plate 96 x 120 mm for 2" x 4" conduit boxes Adapter plate for surface wiring 112x130 mm Mechanical design Type reference ARG70 ARG70. 1 ARG70. 2 The unit consists of two parts: · A plastic housing with digital display, which accommodates the electronics, the operating elements and the built-in room temperatures sensor · A mounting base The housing engages in the mounting base and snaps on. The DIP switch is located at the rear of the housing. 3031Z01 3/8 Siemens Building Technologies HVAC Products Room temperature controllers CE1N3031en 24. 09. 2003 Legend 1 2 3 4 5 6 7 8 Display of the room temperature, setpoints or operating mode changeover time symbol when actual room temperature is displayed Normal operation Energy saving mode symbol when displaying the operating mode changeover time or when the operating mode changeover function is activated heating on symbol indicating that batteries need to be replaced (only with battery-powered versions) Buttons for adjusting the setpoint and the operating mode changeover time Button for operating mode changeover "Normal operation energy saving mode" 9 Button for adjusting the operating mode changeover time 10 Battery compartment (only with battery-powered versions) The required room temperature setpoints for normal operation and energy saving mode and the operating mode changeover time are adjusted with buttons. The operating action for the automatic operating mode changeover function is selected with a DIP switch. DIP switch no. 1 Meaning Operating action of automatic operating mode changeover Position ON Automatic operating mode changeover from normal operation to energy saving mode or OFF Position OFF Automatic operating mode change over from energy saving mode or OFF to normal operation Notes The room temperature controller should be mounted in a location where the air temperature can be measured as accurately as possible without getting adversely affected by direct solar radiation or other heat or refrigeration sources. Mounting height is about 1. 5 m above the floor. The unit can be fitted to a recessed conduit box. The cables used must satisfy the insulation requirements with regard to mains potential Mounting, installation and commissioning When mounting the unit, fix the baseplate first. Then, make the electrical connections and fit and secure the cover (also refer to Mounting Instructions). The controller must be mounted on a flat wall and in compliance with local regulations. 4/8 Siemens Building Technologies HVAC Products Room temperature controllers CE1N3031en 24. 09. 2003 If there are thermostatic radiator valves in the reference room, they must be set to their fully open position. [. . . ] 250 V Application examples N1 T T T T F1 F2 N1 F2 T F1 T Y2 Y2 M1 2222S01 M1 2222S02 Room temperature controller with direct control of a gas-fired wall-hung boiler Room temperature controller with direct control of a gas-fired floor-standing boiler N1 T Y1 M1 2222S03 Room temperature controller with direct control of a heating circuit pump (pre-control by manual mixing valve) F1 F2 M1 Thermal reset limit thermostat Safety limit thermostat Circulating pump N1 Y1 Y2 RDD10. . . room temperatures controller 3-point valve with manual adjustment Magnetic valve Siemens Building Technologies HVAC Products Room temperature controllers CE1N3031en 24. 09. 2003 3031A02 L Ln L Lx 7/8 Dimensions Controller 96 119 23, 8 Baseplate 28 4 28 35 28 11, 8 30 28 89, 45 8/8 Siemens Building Technologies HVAC Products 2003 Siemens Building Technologies AG 3031M02 26 30 112, 3 4 3031M01 Subject to alteration CE1N3031en 24. 09. 2003 Room temperature controllers [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIEMENS RDD10




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SIEMENS RDD10 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.