User manual TEKTRONIX AWG2021 DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TEKTRONIX AWG2021. We hope that this TEKTRONIX AWG2021 user guide will be useful to you.


TEKTRONIX AWG2021 DATASHEET: Download the complete user guide (121 Ko)

Manual abstract: user guide TEKTRONIX AWG2021DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] The standard AWG2021 configuration provides one 5 V output or a second independent 5 V output (Opt. Option 03 adds a 12-Bit wide differential ECL digital port which can be used in conjunction with the marker outputs for data generation up to 14 Bits wide at up to 250 MHz. Or if you prefer, Option 04 provides TTL digital levels with up to two 12-Bit, 100 MS/s ports for a total of 28 Bits wide. The built-in frequency domain (FFT) editor (Opt. [. . . ] 03, eliminates RS-232 Interface) ­ Level: Differential ECL compatible. Connector: 68-Pin mini-D sub. Auxiliary Inputs Frequency Range ­ 10 Hz to 250 MHz. 02 only) ­ Within 4 ns. Operating Modes Continuous ­ Output continuous at programmed waveshape, frequency, amplitude and offset. Triggered ­ Output quiescent until triggered by an external, GPIB or manual trigger; then generates a sequence only one time. Gated ­ Same as triggered mode except period is executed only for the duration of the gated signal until the sequence started is completed. Burst ­ Output quiescent until triggered by an external, GPIB or manual trigger; then generates "n" sequences or cycles. Waveform Advance ­ Continuously generates the waveform in a predefined sequence; the next trigger advances to the next waveform in sequence. Autostep ­ Generates the predefined waveform once in the Autostep File; the next trigger advances the waveform. AM (Multiply) ­ Output: Within 5%. External AM ­ Sensitivity: 2 Vp-p (±5%) signal produces 100% modulation. Frequency Response: DC to 30 MHz. Filters Trigger ­ Threshold Level: ­5 V to +5 V. Maximum Input Volts: 10 Vp-p when 1 M selected; 5 VRMS when 50 selected. Trigger to Output Signal Delay: External clock, 100 ns maximum +1 clock. Frequency Range: Up to 250 MHz phase coherent. Programmable Interface 3 dB Cutoff Frequency ­ 1 MHz: Within 20%. RS-232 ­ 9-Pin D connector. 2 Arbitrary Waveform Generators · www. tektronix. com/signal_sources Arbitrary Waveform Generator AWG2021 Environmental Temperature ­ Operating: +10 ºC to +40 ºC. Temperature Change ­ Operating: +15 ºC per hour (no condensation). Maximum operating temperature decreases 1 ºC for each 300 m above 1. 5 km. Vibration ­ Operating: 0. 33 mm p-p, 10 Hz to 55 Hz for 15 minutes. Bench Handling ­ Operating: Drop from 10 cm (4 in. ) tilt or 45º, whichever is less. [. . . ] at: 1 (503) 627-7111 Updated 20 September 2002 Our most up-to-date product information is available at: www. tektronix. com Product Area Assessed: The planning, design/development and manufacture of electronic Test and Measurement instruments. Product(s) complies with IEEE Standard 488. 1-1987, RS-232-C, and with Tektronix Standard Codes and Formats. Copyright © 2003, Tektronix, Inc. Information in this publication supersedes that in all previously published material. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTRONIX AWG2021




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTRONIX AWG2021 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.