User manual TEKTRONIX DIGITAL SERIAL ANALYZER SAMPLING OSCILLOSCOPE DSA8200 DATA SHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TEKTRONIX DIGITAL SERIAL ANALYZER SAMPLING OSCILLOSCOPE DSA8200. We hope that this TEKTRONIX DIGITAL SERIAL ANALYZER SAMPLING OSCILLOSCOPE DSA8200 user guide will be useful to you.


TEKTRONIX DIGITAL SERIAL ANALYZER SAMPLING OSCILLOSCOPE DSA8200 DATA SHEET: Download the complete user guide (978 Ko)

Manual abstract: user guide TEKTRONIX DIGITAL SERIAL ANALYZER SAMPLING OSCILLOSCOPE DSA8200DATA SHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Digital Serial Analyzer Sampling Oscilloscope DSA8200 Data Sheet Jitter, Noise, BER, and Serial Data Link Analysis Measures and Separates Deterministic Data-dependent Jitter from Random Jitter Measures Vertical Noise, Separating Deterministic Data-dependent Noise from Random Noise Highly Accurate BER and Eye Contour Estimation, Support for DDPWS FFE/DFE Equalization, Transmitter Equalization Channel Emulation for Channels with >30 dB of Loss Linear Filter for Fixture De-embedding, Linear Filtering TDR (Time Domain Reflectometry) Up to 50 GHz TDR Bandwidth with 15 ps Reflected Rise Time and 12 ps Incident Rise Time Lowest Noise for Accurate Repeatable TDR Measurement Results ­ 600 VRMS at 50 GHz Independent Sampler Deskew ensures Easy Fixture and Probe De-embedding Industry's Only Mainframe to Accommodate up to Four True-differential TDR or Electrical Channel Pairs for Increased System Versatility S-parameters Measurements Up to 50 GHz Differential, Single Ended, Mixed Mode; Insertion, Return Loss, Frequency Domain Crosstalk PCI Express, Serial ATA, Infiniband, Gigabit Ethernet Manufacturing, and Standard Compliance Testing for Gigabit Signal Path and Interconnects ­ Including Eye Mask Tests Intuitive, Easy, and Accurate for Serial Data, Gigabit Digital Design, and Signal Integrity Fast and Accurate Automated Multiport S-parameter Measurements with Command Line Interface Industry's Best Standard Time-base Jitter Performance, 800 fsRMS Industry-leading Time-base Jitter Performance, <200 fsRMS*1 Available with Phase Reference Mode Fast Acquisition Rate and High Throughput True-differential Remote Sampler enabling Placement Near DUT for Superior Signal Fidelity FrameScanTM Acquisition Mode with Eye Diagram Averaging: Isolate Data-dependent Faults Examine Low-power Signals MS Windows XP Operating System Advanced Connectivity to 3rd party Software Features & Benefits State-of-the-Art Sampling Oscilloscope for Communication Signal Analysis, TDR / TDT / Serial Data Network Analysis, Acquisition, and Measurements of Repetitive Ultrafast Signals Acquisition of Spread Spectrum Clocking (SSC) Signals Industry's Only Mainframe to Support up to 8 Input Channels for Increased Flexibility and Throughput Four Color-graded, Variable Persistence Waveform Databases Measurement System with Over 100 Automated Measurements Complete Suite of Communications Measurements includes Both Types of OMA, SSC Profile, and Many Others Automated ITU/ANSI/IEEE Mask Testing Masks and Measurements for SONET/SDH, FC, Ethernet, and Other Standards Built-in Mask Updates can be Loaded from Factory-supplied File Mask Margin Testing for Guard Banding Production Testing Acquisition Modules Fully Integrated Multirate Optical Modules Optical Modules up to 80 GHz 80C10B High-accuracy "ER Calibrated" Measurement Available in Some Modules Electrical Modules up to 70+ GHz Bandwidth and 5 ps Measured Rise Time (10-90%) Flexible Rate Clock Recovery Clock Recovery with SSC (Spread Spectrum Clocking) Support Available Data Sheet Applications Design/Verification of Telecom and Datacom Components and Systems Manufacturing/Testing for ITU/ANSI/IEEE/SONET/SDH Compliance High-performance True-differential TDR Measurements Advanced Jitter, Noise, and BER Analysis Impedance Characterization and Network Analysis for Serial Data Applications including S-parameters Channel and Eye Diagram Simulation and Measurement-based SPICE Modeling *1 Typical, with the Phase Reference module, some conditions apply. Without the module, the jitter is <800 fsRMS (typical). samplers, offer up to 50 GHz bandwidth and 15 ps reflected rise time and 12 ps incident rise time. The family of low-noise variable-bandwidth electrical modules provides the industry's best noise performance with remote samplers, featuring 450 VRMS noise at 60 GHz, and 300 VRMS at 30 GHz. DSA8200 optical modules provide complete optical test solutions with superior system fidelity from 125 Mb/s to 43 Gb/s and beyond. [. . . ] The module accepts either single-ended or differential signals as its input, providing clock recovery for both. The signal(s) is/are then passed on to the output connectors (at about 50% of the input level) and can be connected to sampling module(s) for differential or single-ended sampling. Option 10G is required for support of standard rates from 9. 953 Gb/s to 12. 6 Gb/s. The 80A05 and 80A07 can also serve as the Clock Recovery module for the 80C12 Optical Sampling module. 80A06 PatternSync Module The 80A06 PatternSync Trigger module, when used in combination with 80SJNB software, enables characterizing jitter, noise, and BER performance of high-speed serial designs from 1 Gb/s to 60 Gb/s data rates. It extends the capability of the DSA8200 sampling oscilloscope by creating a pattern trigger from any data-related clock ­ a recovered clock, user-supplied clock, sub-clock, or super-clock. The PatternSync Trigger module is programmable to pattern lengths of up to 223 bits and accepts a user-supplied clock signal from 150 MHz to 12. 5 GHz. The 80A06 module is required with the DSA8200 when using 80SJNB Advanced Jitter, Noise, and BER Analysis software package. This module can be used in combination with the 82A04 Phase Reference module for the best time-base accuracy or for acquisition of signals under SSC (Spread Spectrum Clocking). 80A07 Clock Recovery Module 80A07 recovers clocks from serial data streams for all of the most common electrical standards in the continuous 100 Mb/s to 12. 5 GB/s range. Auto-locking capability is selectable from the user interface or programmatic interface, so the design and test engineers can search and lock onto signals of undefined or unknown data rate. The module accepts either single-ended or differential signals as its input, providing clock recovery for both. The signal(s) is/are then passed on to the output connectors and can be connected to sampling module(s) for differential or single-ended sampling. 80A07 offers complete configurability and state-of-the-art specifications and is the preferred solution for most serial data standards due to excellent stability, superior jitter and slew rate tolerance for recovering clocks from stressed or degraded signals, and unequaled PLL bandwidth and roll-off shape control for either Golden PLL compliance testing or custom PLL response. The 80A07 can also serve as the Clock Recovery module for the 80C12 Optical Sampling module. P80318 Differential Handheld TDR Probe The P80318 is an 18 GHz 100 input impedance differential TDR hand probe. This probe enables high-fidelity impedance measurements of differential transmission lines. The adjustable probe pitch from 0. 5 mm to 4. 2 mm enables a wide variety of differential line spacing and impedances. The P80318 probe also includes two precision SMA cables with parallel control lines that provides the 80A02 module the control for EOS/ESD protection. P8018 Single-ended Handheld TDR Probe The P8018 Handheld TDR Probe is a 20 GHz, 50 input impedance, single-ended passive probe that provides a high-performance solution for electrical sampling, TDR circuit board impedance characterization, and high-speed electrical signal analysis applications. The P8018 probe also includes a precision SMA cable and parallel control line that provides the 80A02 module the control for EOS/ESD protection. 80A02 EOS/ESD Protection Module The 80A02 EOS/ESD Protection module protects the sampling bridge of Tektronix electrical sampling module inputs from damage by electrostatic charge. The 80A02 is intended for use in applications such as electrical TDR circuit board testing and cable testing where large static charges can be stored in the DUT. [. . . ] Requires 80A03 Interface module 5 GHz 50 Differential to Single-ended Active Probe. Note that the P7380 probes are recommended over the P7350 probes for sampling purposes due to their higher bandwidth and signal fidelity 8 GHz 50 Differential to Single-ended Active Probe. Requires 80A03 Interface module 9 GHz Passive Probe; the probe consists of a very high-quality 20 GHz probe tips, plus an extremely flexible SMA cable. For higher frequency performance the 015-0560-xx, or some of the accessory cables listed can be used 20 GHz Single-ended TDR Probe. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTRONIX DIGITAL SERIAL ANALYZER SAMPLING OSCILLOSCOPE DSA8200




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTRONIX DIGITAL SERIAL ANALYZER SAMPLING OSCILLOSCOPE DSA8200 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.