User manual TEKTRONIX DPO5000 DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TEKTRONIX DPO5000. We hope that this TEKTRONIX DPO5000 user guide will be useful to you.


TEKTRONIX DPO5000 DATASHEET: Download the complete user guide (2647 Ko)

You may also download the following manuals related to this product:

   TEKTRONIX DPO5000 BROCHURE (6710 ko)
   TEKTRONIX DPO5000 DATASHEET (1447 ko)
   TEKTRONIX DPO5000 DATASHEET (393 ko)

Manual abstract: user guide TEKTRONIX DPO5000DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Mixed Signal Oscilloscopes MSO5000, DPO5000 Series Data Sheet 53 Automated Measurements, Waveform Histograms, and FFT Analysis for Simplified Waveform Analysis TekVPI® Probe Interface supports Active, Differential, and Current Probes for Automatic Scaling and Units 10. 4 in. (264 mm) Bright XGA Display with Touch Screen Small Footprint and Lightweight ­ Only 8. 12 in. (6. 7 kg) Connectivity Two USB Host Ports on the Front Panel and Four on the Rear Panel for Quick and Easy Data Storage, Printing, and Connecting USB Peripherals USB Device Port on the Rear Panel for Easy Connection to a PC or GPIB Control with an Adapter Features & Benefits Key Performance Specifications 2 GHz, 1 GHz, 500 MHz, and 350 MHz Bandwidth Models Up to 10 GS/s Real-time Sample Rate on One or Two Channels and up to 5 GS/s on All Four Channels Up to 250 Megapoint Record Length with MultiView ZoomTM >250, 000 wfms/s Maximum Waveform Capture Rate with FastAcqTM FastFrame Segmented Memory Acquisition Mode with >310, 000 Frames per Second Capture Rate Standard Passive Voltage Probes with Less than 4 pF Capacitive Loading and 500 MHz or 1 GHz Analog Bandwidth 16 Digital Channels (MSO Series) User-selectable Bandwidth Limit Filters for Better Low-frequency Measurement Accuracy Suite of Advanced Triggers Integrated 10/100/1000BASE-T Ethernet Port for Network Connection and Video Out Port to Export the Oscilloscope Display to a Monitor or Projector Microsoft® Windows 7 64-bit Operating System for Easy Connectivity and Integration into Your Environment LXI Class C Compliant Mixed Signal Design and Analysis (MSO Series) Automated Triggering and Decode on Parallel Buses Per-channel Threshold Settings MagniVuTM High-speed Acquisition provides 60. 6 ps Fine Timing Resolution on Digital Channels Optional Serial Triggering and Analysis Automated Serial Triggering and Decode Options for I2C, SPI, RS-232/422/485/UART, and USB Automated Serial Decode and Vehicle Network Monitoring of CAN and LIN Ease-of-Use Features Wave Inspector® Controls provide Easy Navigation and Automated Search of Waveform Data MyScope® Custom Control Windows and Right Mouse Click Menus for Exceptional Efficiency Optional Technology Specific Analysis Software Solutions provide Built-in Domain Expertise for Ethernet and USB 2. 0 Compliance Testing, Jitter, Timing, Eye Diagrams, Power, and DDR Memory Bus Analysis Limit and Mask Testing provide Quick Insight into Signal Characteristics Data Sheet all channels and an optional record length of up to 250M points on two channels. With Wave Inspector® controls for rapid waveform navigation, and more than 10 optional software and analysis packages for common technologies and in-depth analysis tasks, the MSO/DPO5000 Series from Tektronix provides the feature-rich tools you need to simplify and speed debug of your complex design. Comprehensive Features Speed Every Stage of Debug The MSO/DPO5000 Series offers a robust set of features to speed every stage of debugging your design ­ from quickly discovering an anomaly and capturing it, to searching your waveform record for the event and analyzing its characteristics and your device's behavior. Discover ­ Fast waveform capture rate - over 250, 000 wfm/s - maximizes the probability of capturing elusive glitches and other infrequent events. Feature-rich Tools for Debugging Mixed Signal Designs With the MSO/DPO5000 Mixed Signal Oscilloscope Series, you can analyze up to 20 analog and digital signals with a single instrument to quickly find and diagnose problems in complex designs. [. . . ] Additionally, custom masks can be created and used for characterizing signals. With both software packages you can tailor a test to your specific requirements by defining test duration in a number of waveforms, setting a violation threshold that must be met before considering a test a failure, counting hits along with statistical information, and setting actions upon violations, test failure, and test complete. Whether specifying a limit template or a mask, conducting pass/fail tests in search of waveform anomalies such as glitches has never been easier. Connectivity Two USB host ports on the front panel enable easy transfer of screenshots, instrument settings, and waveform data to a USB thumb drive. The rear panel contains four additional USB host ports and a USB device port for controlling the oscilloscope remotely from a PC or for connecting USB peripherals. An integrated 10/100/1000BASE-T Ethernet port enables easy connection to networks and a Video Out port allows the oscilloscope display to be exported to an external monitor or projector. PS-2 ports for keyboard and mouse are included for security-conscious applications that require the USB ports to be disabled. A standard removable hard disk drive makes customizing settings for different users easy as well as enables use in secure environments. www. tektronix. com 9 Data Sheet The MSO/DPO5000 Series' compact form factor frees up valuable space on your bench. MyScope custom control windows are created with a simple drag-and-drop process enabling each user to have a unique interface. menu button right on the probe itself. This button brings up a probe menu on the oscilloscope display with all relevant settings and controls for the probe. The TekVPI interface enables direct attachment of a current probe without requiring a separate power supply. TekVPI probes can be controlled remotely through USB, GPIB, or Ethernet, enabling more versatile solutions in ATE environments. TekVPI probe interface simplifies connecting your probes to the oscilloscope. MyScope® Custom Control Window Easily create your own personalized "toolbox" of oscilloscope features in a matter of minutes using a simple, visual, drag-and-drop process. Once created, these custom control windows are easily accessed through a dedicated MyScope menu selection on the oscilloscope. This is ideal in a shared resource environment where each person can have their own custom control interface suited to their particular use. MyScope control windows benefit all oscilloscope users, eliminating the ramp-up time that many face when returning to the lab after not using an oscilloscope for a while, and enabling power users to be far more efficient. Floating Licenses Floating licenses offer an alternative method to manage your Tektronix asset. Floating licenses allow license-key enabled options to be easily moved among all your MSO/DPO5000, DPO7000, and DPO/DSA/MSO70000 Series of Tektronix oscilloscopes. To order a floating version of an option license add "DPOFL-" prefix to the option name. DPOFL-ET3) Check www. tektronix. com for additional information about floating license options. Compact Form Factor A compact, portable form factor allows the MSO/DPO5000 Series to be easily moved between labs and, with a depth of just 8. 12 in. Additionally the 5U rack height makes the MSO/DPO5000 Series an ideal choice for ATE applications where rack space is limited. TekVPI® Probe Interface The TekVPI probe interface sets the standard for ease of use in probing. TekVPI probes feature status indicators and controls, as well as a probe 10 www. tektronix. com Mixed Signal Oscilloscopes -- MSO5000, DPO5000 Series Capture data into Microsoft Excel using the unique Excel toolbar, and create custom reports using the Word toolbar. Remote Operation and Extended Analysis There are many ways to connect to your MSO/DPO5000 Series oscilloscope to conduct extended analysis. The first makes use of the Windows Remote Desktop capability ­ connect directly to your oscilloscope and operate the user interface remotely through the built-in Remote Desktop. A second way to connect is through Tektronix OpenChoice® software which makes use of the fast embedded bus, transferring waveform data directly from acquisition to analysis applications on the Windows desktop at much faster speeds than conventional GPIB transfers. [. . . ] Also enables analytical tools such as digital views of the signal, bus views, and packet decoding for low-speed, full-speed, and high-speed USB serial buses. Signal Inputs ­ Low-speed and Full-speed: Any Ch1 - Ch4 (and any D0 - D15 on MSO models) for single ended, Any Ch1 - Ch4 for differential; High-speed: Any Ch1 - Ch4 Recommended Probing ­ Low-speed and Full-speed: Single ended or differential; High-speed: Differential USB high-speed supported only on MSO5204, DPO5204, MSO5104, and DPO5104 models. USB 2. 0 Compliance Testing CAN/LIN Protocol Analysis Software Power Plug Options Option Description Opt. Opt. A0 A1 A2 A3 A5 A6 A10 A11 A12 A99 North America Universal European Union UK Australia Switzerland Japan China India Brazil No power cord User Manual Options Option Description Opt. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTRONIX DPO5000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTRONIX DPO5000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.