User manual TEKTRONIX OI1125 DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TEKTRONIX OI1125. We hope that this TEKTRONIX OI1125 user guide will be useful to you.


TEKTRONIX OI1125 DATASHEET: Download the complete user guide (1051 Ko)

Manual abstract: user guide TEKTRONIX OI1125DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] The adjustable extinction ratio allows testing the receiver sensitivity at worst-case conditions without complex test setups. The OI1125 also generates optical signals for optical signal analysis of components, systems and subsystems using a CSA8000 sampling oscilloscope. Receiver Clock Recovery and Multi-data Rate Support Simplify Testing of High-performance Optical Transmitters, Laser Diodes, Optical Components and Fiber Loops Applications Bit Error Rate Testing Optical Receiver and Transmitter Testing Optical Component and Fiber Loop Testing Optical Signal Analysis Remote Operation for System Integration Using the internal 1550 nm DFB laser or an external C-band tunable laser, the OI1125 is excellent for generating optical signals modulated by a high-performance pattern generator and is designed so most commercial generators connect directly to the modulation input. The OI2125 O/E Receiver receives modulated optical signals up to 12. 5 Gb/s from transmission systems, including SONET/SDH compatible systems, and converts them to electrical signals for further testing by equipment such as a bit error rate tester (BERT). The OI2125 electrical output can be connected 1 Optical Transmission Test · www. tektronix. com/optical Optical Transmitter and Receiver OI1125 · OI2125 O I 1 1 2 5 E / O Tr a n s m i t t e r S p e c i f i c a t i o n s Specification Min Typ Max Units Comments Data Rate*1 Data Input Voltage Int. [. . . ] Used with the Tektronix TDS/CSA8000 series sampling oscilloscope and a pattern generator, the OI1125 can create modulated optical signals for high-speed optical communications testing, extinction ratio measurements, eye-pattern analysis and optical signal analysis. The optical signal is passed through the DUT and received by the appropriate 80Cxx sampling head on the oscilloscope. A single receiver with the OM1420 and OM1200 modules supports a broad range of signal bit rates. The OM1420 OC-192 Dual-rate Clock Recovery Module supports standard OC-192 (9. 953 Gb/s) and OC-192 FEC (10. 664 Gb/s). The OM1200 OC-48 Multi-rate Clock Recovery Module supports OC-48 (2. 488 Gb/s), OC-48 FEC (2. 666 Gb/s), OC-12 (622 Mb/s) and OC-3 (155 Mb/s) rates. 2 Optical Transmission Test · www. tektronix. com/optical Optical Transmitter and Receiver OI1125 · OI2125 Physical Characteristics OI2125 O/E Receiver Specifications Specification Min Typ Max Units Comments Data Rate Wavelength (typical)*5 Input Power Loss of Signal Threshold Input Fiber Size Data Output Voltage 2. 4 1100 ­16 ­27 0. 05 0. 2 ­25 9 12. 5 1620 +0 -23 1. 5 1. 5 Gb/s nm dBm dBm µm Vp-p Vp-p GHz ­8 to +0 dBm input power ­16 to ­8 dBm input power OI1125 E/O TRANSMITTER Dimensions mm Height 45 Width 204 Depth 331 Weight kg Instrument only 1. 72 OI2125 O/E RECEIVER Dimensions Height Width Depth Weight Instrument only With slot cover installed With OM1420 installed With OM1200 installed in. 3. 79 Upper Bandwidth Lower Bandwidth Jitter (rms) Percent Crossing Eye Mask Testing*6 7. 5 50 1. 5 45 55 GR-1377-CORE GR-253-CORE MHz psRMS % ­8 to +0 dBm input power mm 45 204 331 kg 1. 91 2. 09 2. 26 2. 26 in. 4. 20 4. 62 4. 99 4. 99 *5 Manufacturer specifications for the photodiode are 1100 to 1620 nm. The OI2125 specifications are tested and verified for 1530 to 1565 nm, but are not verified beyond this range. *6 No mask hits with 5% mask margin for OC-48, OC-192 and 12. 4 Gb/s (scaled OC-192 mask) at an input power of 0 to ­8 dBm. For input power levels down to ­16 dBm, a minimum BER of 10­12 is typical for rates up to OC-192, and 10­10 for rates above OC-192. SHIPPING WEIGHT WITH PACKAGING Instrument/Module kg OI1125 5. 12 OI2125 5. 49 RACKMOUNT Dimensions Height Width Depth lbs. 3. 5 19 18. 75 Characteristics Environment Power Supply Rating ­ 100 to 240 VAC. Frequency ­ 47 to 63 Hz. I/O Interface Temperature ­ Operating: 0°C to +40°C. EMC Compliance ­ Meets or exceeds EN55011 Class A Radiated and Conducted Emissions; FCC47 CFR, Part 15, Subpart B, Class A. Safety ­ UL3111-1; CSA1010. 1; EN61010-1; IEC61010-1. Ordering Information OI1125 E/O Transmitter Instrument ­ OI1125. Service Options OI1125 E/O Transmitter ­ Laser In (Optical) FC/APC PMF. D5 ­ Calibration data report, must order with C5. Optical Transmission Test · www. tektronix. com/optical 3 Optical Transmitter and Receiver OI1125 · OI2125 Included Accessories Included Accessories Contact Tektronix: ASEAN Countries & Pakistan (65) 6356 3900 Australia & New Zealand (65) 6356 3900 Austria +43 2236 8092 262 Belgium +32 (2) 715 89 70 Brazil & South America 55 (11) 3741-8360 Canada 1 (800) 661-5625 Central Europe & Greece +43 2236 8092 301 Denmark +45 44 850 700 Finland +358 (9) 4783 400 France & North Africa +33 (0) 1 69 86 80 34 Germany +49 (221) 94 77 400 Hong Kong (852) 2585-6688 India (91) 80-2275577 Italy +39 (02) 25086 1 Japan (Sony/Tektronix Corporation) 81 (3) 3448-3111 Mexico, Central America & Caribbean 52 (55) 56666-333 The Netherlands +31 (0) 23 569 5555 Norway +47 22 07 07 00 People's Republic of China 86 (10) 6235 1230 Poland +48 (0) 22 521 53 40 Republic of Korea 82 (2) 528-5299 Russia, CIS & The Baltics +358 (9) 4783 400 South Africa +27 11 254 8360 Spain +34 (91) 372 6055 Sweden +46 8 477 6503/4 Taiwan 886 (2) 2722-9622 United Kingdom & Eire +44 (0) 1344 392400 USA 1 (800) 426-2200 For other areas contact Tektronix, Inc. at: 1 (503) 627-7111 Updated 8 February 2002 071-1052-00 ­ User Reference: English only. [. . . ] 119-5887-00 ­ DIN/APC 47256 Optical Adapter. Power Cord Options A1 ­ Universal European power cord (220 V, 50 Hz). A99 ­ No power cord. OI2125 O/E Receiver OM1420 ­ OC-192 Dual-rate Clock Recovery Module. 119-4558-00 ­ Diamond 3. 5 Optical Adapter. Power Cord Options Instrument ­ OI2125. Service Options Opt. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTRONIX OI1125




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTRONIX OI1125 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.