User manual TEKTRONIX TLA6000 DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TEKTRONIX TLA6000. We hope that this TEKTRONIX TLA6000 user guide will be useful to you.


TEKTRONIX TLA6000 DATASHEET: Download the complete user guide (408 Ko)

You may also download the following manuals related to this product:

   TEKTRONIX TLA6000 DATASHEET (672 ko)
   TEKTRONIX TLA6000 DATASHEET (211 ko)

Manual abstract: user guide TEKTRONIX TLA6000DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Tektronix Logic Analyzers TLA6000 Series Data Sheet Performance and Ease of Use to Debug, Validate, and Optimize Digital Systems 125 ps Resolution MagniVuTM Acquisition to Accurately See Signal Relationships in Your System State Speed ­ Sample your fastest synchronous buses with clock rates up to 800 MHz and data rates up to 1. 25 Gb/s 15 in. Display, with Optional Touch Screen to See More of Your Data and Navigate Efficiently through Your Data 3 Models with 68/102/136 Channels and Up to 128 Mb Record Length offer Flexible Solutions to Fit Any Budget Drag-and-Drop Triggering ­ Simply drag any one of eight different trigger types from a table onto the waveform and the TLA will automatically set up the trigger conditions. Eliminates errors, improves repeatability, and saves time Drag-and-Drop Measurements ­ Simply drag an icon from the measurement toolbar and drop it on your signal of interest and get a table of results. [. . . ] These tools allow you to: Use glitch trigger to monitor selected signals in your design and trigger when a signal integrity problem is found on any one of these signals Automatically tag any found signal integrity problems, allowing you to quickly identify the signals of interest Gain more insight into the problem using the exclusive iCapture functionality to view both digital and analog data through a single probe Use iView to see time-correlated digital and analog displays of your data, letting you track the signal integrity problem across both analog and digital domains Number of Channels (All channels are acquired including clocks) TLA6202 TLA6203 TLA6204 Channel grouping 68 channels (4 are clock channels) 102 channels (4 are clock and 2 are qualifier channels) 136 channels (4 are clock and 4 are qualifier channels) No limit to number of groups or number of channels per group (all channels can be reused in multiple groups) 51 bits at 125 ps resolution (3. 25 days duration) Asynchronous/Synchronous 8 GHz MagniVu high-speed timing is available simultaneous with all modes The TLA6000 Series can be used as either a master or expansion mainframe in systems consisting of up to 8 TLA6000/TLA7000 instruments. A TL708EX Instrument Hub and Expander is required when connecting 3-8 instruments together using TekLinkTM cables Time Stamp Clocking/Acquisition Modes Expansion Capability 2 www. tektronix. com Tektronix Logic Analyzers -- TLA6000 Series PC Characteristics Characteristic Description Symbolic Support Characteristic Description Operating System Processor Chipset Memory Sound Removable Hard Drive Optical Drive External Display Port Type External Display Resolution Network Port USB 2. 0 Port Microsoft® Windows® XP Professional and Multilingual User Interface Pack 2. 2 GHz Intel Core 2 Duo T7500 Intel® 965GME 1 GB DDR2 expandable to 2 GB DDR memory Line In, Line Out, and Mic Out connectors 3. 5 in. , 80 GB Serial ATA, 7200 RPM Internal 4. 7 GB DVD±R/RW One (1) DVI-I (primary ­ digital and analog) connector and one (1) VGA connector Up to 1600×1200 noninterlaced at 32-bit color, each for both primary and secondary displays Two (2) 10/100/1000 LAN with RJ-45 connector Seven (7); three (3) in front and four (4) in rear Number of Symbols/Ranges Object File Formats Supported Unlimited (limited only by amount of virtual memory available on TLA) IEEE695, OMF 51, OMF 86, OMF 166, OMF 286, OMF 386, COFF, Elf/Dwarf 1 and 2, Elf/Stabs, TSF (If your software development tools do not generate output in one of the above formats, TSF, or the Tektronix symbol file, a generic ASCII file format is supported. If a format is not listed, please contact your local Tektronix representative External Instrumentation Interfaces Characteristic Description System Trigger Output Asserted whenever a system trigger occurs (TTL-compatible output, back-terminated into 50 ) Forces a system trigger (triggers all modules) when asserted (adjustable threshold between 0. 5 V and 1. 5 V, edge sensitive, falling-edge latched) Can be used to drive external circuitry from a module's trigger mechanism (TTL-compatible output, back-terminated into 50 ) Can be used to provide an external signal to arm or trigger any or all modules (adjustable threshold between 0. 5 V and 1. 5 V, level sensitive) Integral Controls Characteristic Description System Trigger Input Front-panel Display Size: 15 in. (38. 1 cm) diagonal Type: Active-matrix color TFT LCD with backlight Resolution: 1024×768 Both the front-panel and one external display can be used simultaneously at 1024×768 resolution General-purpose knob with dedicated hotkeys and knobs for horizontal and vertical scaling and scrolling Available with Option 18 External Signal Output Simultaneous Display Capability Front Panel External Signal Input Touch Screen Power Voltage Range/Frequency: 90-250 V AC at 45-66 Hz, 100-132 V AC at 360-440 Hz Input Current: 7 A maximum at 90 V AC (70 A surge) Power Consumption: 750 W maximum Integrated View (iViewTM) Capability Characteristic Description TLA Mainframe Configuration Requirements Number of Tektronix Oscilloscopes that can be Connected to a TLA System External Oscilloscopes Supported TLA Connections Oscilloscope Connections Setup Data Correlation GPIB-iView (Opt. 1C) requires TLA Application Software 5. 0 or greater 1 Environmental Characteristic Description Temperature More than 100. For a complete listing of currently supported oscilloscopes, please visit our website http://www. tektronix. com/iview USB, Trigger In, Trigger Out, Clock Out GPIB, Trigger In, Trigger Out, Clock In (when available) for the GPIB-iView cable (Opt. 1C) iViewTM external oscilloscope wizard automates setup After oscilloscope acquisition is complete, the data is automatically transferred to the TLA and time correlated with the TLA acquisition data The oscilloscope and TLA data is automatically deskewed and time correlated when using the iViewTM external oscilloscope cable 2m Altitude Safety Humidity Operating: +5 °C to +45 °C Nonoperating: ­20 °C to +60 °C 20% to 80% Operating: 30 °C; 80% relative humidity (29 °C maximum wet-bulb temperature) Nonoperating: 8% to 80% (29 °C maximum wet-bulb temperature) Operating: ­1, 000 ft. Can be as wide as any group, must be grouped according to specified order of significance From 8 ns before to 7 ns after clock edge in 125 ps increments. This range may be shifted towards the positive region by 0 ns, 4 ns, or 8 ns From 7 ns before to 8 ns after clock edge in 125 ps increments. This range may be shifted towards the positive region by 0 ns [+8, ­8] ns, 4 ns [+12, ­4] ns, or 8 ns [+16, 0] ns Any data sample MagniVu position can be set from 0% to 60% centered around the MagniVu trigger Global (conditional), by state (start/stop), block, by trigger action, or transitional. Also force main prefill selection available Trigger Action Types Maximum Triggerable Data Rate Trigger Sequence Rate Counter/Timer Range Counter Rate Timer Clock Rate Counter/Timer Latency Range Recognizers Setup-and-Hold Violation Recognizer Setup Time Range Setup-and-Hold Violation Recognizer Hold Time Range Trigger Position MagniVu Trigger Position Storage Control (Data qualification) www. tektronix. com 5 Data Sheet Ordering Information TLA6202 TLA6203 TLA6204 68-channel Logic Analyzer module, 8 GHz timing, 235 MHz state, 2 Mb record length. 102-channel Logic Analyzer module, 8 GHz timing, 235 MHz state, 2 Mb record length. 136-channel Logic Analyzer module, 8 GHz timing, 235 MHz state, 2 Mb record length. All Include: Mini Keyboard (119-7275-xx), Optical Wheel Mouse (119-7054-xx), Front-panel cover (200-4939-xx), TLA Application Software CD (063-3881-xx), Certificate of Traceable Calibration. [. . . ] Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Information in this publication supersedes that in all previously published material. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTRONIX TLA6000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTRONIX TLA6000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.