Detailed instructions for use are in the User's Guide.
[. . . ] (Press REW again to adjust speed as 1, 2, 4, 8, 16, 32 times) Left : Under setup mode, it works as Left button. FF : It can play video forward at high speed, and press FF again to adjust speed from 1, 2, 4, 8, 16, 32 times. HDD Full : HDD is full ALARM : If Alarm Enable sets as "YES", while the alarm is triggered , the led will be flashing TIMER : When Timer is set as Enabled PLAY : On Play mode REC : On Recording mode AUTO : 4 channel will display in full screen by turns
14.
: Displays the CH1 camera : Displays the CH2 camera : Displays the CH3 camera : Displays the CH4 camera QUAD : Display 4 cameras in Quad screen format AUTO : 4 channel will display in full screen format by turns
6
BACK PANEL
IN OUT
DQR
3 R
PO W E R
MONITOR 1
EXTERNAL I/O
RI SK O F ELECTRI C SHO CK D O NOT O PE N
WAR NING : TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
2
4
L
V IDEO 1
2
3
4
1. [. . . ] For specific date of Recording Timer Schedule, it is not recommended to set End Time over 23:59. For Example:If you set Timer Schedule Day as Sunday, and START from 11:30, but End on 00:20, then Recording Timer Schedule is set as from every Sunday's 11:30 to next Sunday's 00:20. If you only want to set Recording Timer Schedule from every Sunday 11:30 to Monday 00:20, then you should set Recording Timer Schedule as Sunday from 11:30 to 23:59, and Monday from 00:00 to 00:20.
(MENU) TIMER CAMERA RECORD ALARM DWELL REMOTE SYSTEM EVENT
2. IPS
Stand for Images Per Second and it could let you see Record submenu for more details. NTSC603015842 1OFF PAL502512632 1OFF
(TIMER) DAY START END IPS DAILY 00:00 00:00 OFF DAILY 00:00 00:00 OFF DAILY 00:00 00:00 OFF DAILY 00:00 00:00 OFF DAILY 00:00 00:00 OFF DAILY 00:00 00:00 OFF DAILY 00:00 00:00 OFF DAILY 00:00 00:00 OFF TIMER ENABLE : YES
5. TIMER ENABLE
Enables / Disables Timer recording function
CAMERA
_ _ _ CH1_ _ _ _ _ _ _ CH2_ _ _ _ : 5 BRIGHTNESS :5 BRIGHTNESS CONTRAST : 5 CONTRAST :5 COLOR : 5 COLOR :5
(MENU) TIMER CAMERA RECORD ALARM DWELL REMOTE SYSTEM EVENT
_ _ _ CH3_ _ _ _ _ _ _ CH4 _ _ _ BRIGHTNESS : 5 BRIGHTNESS CONTRAST : 5 CONTRAST COLOR : 5 COLOR
:5 :5 :5
1. Brightness / Contrast / Color
Have a video adjustment (Brightness / Contrast / Color) of each channel. The options are as following : NTSC603015842 1 PAL502512632 1 (MENU) TIMER CAMERA RECORD ALARM DWELL REMOTE SYSTEM EVENT
2. RECORD QUALITY
There are four quality settings : BEST, HIGH, NORMAL and BASIC. NOTE : The relationship of Record time, IPS and record quality, please refer to page. 23 Recording Speed.
3. RECORD IPS : 60 NOTE : It is recommended that you leave the Record Mode as Field. ALARM DURATION
Set the length of time for recording after Alarm trigger.
3. The options are as following : NTSC603015842 1 PAL502512632 1
(MENU) TIMER CAMERA RECORD ALARM DWELL REMOTE SYSTEM EVENT
4. RECORD QUALITY
(RECORD) There are four quality settings : BEST, HIGH, NORMAL and BASIC. ALARM ENABLE : YES NOTE : The relationship of Record time, IPS and record quality, please refer to ALARM DURATION : 10 SEC page. 23 Recording Speed. NOTE : It is recommended that you leave the Record Mode as Field.
DWELL
1. DWELL TIME
(DWELL) DWELL TIME : 02 DWELL TIME is the time period that each channel sequentially CH1 : YES shown on monitor. CH1-CH4 CH4 : YES YES-Chose channel will be showed on the screen sequentially. REMOTE MODE
Select RS-232 or RS-485 interface for the remote computer connection Protocol. BAUD RATE
Set the speed of the remote computer's Baud Rate which is the rate of Data transmission. Available Baud Rate are 115200, 57600, 19200, 9600, 4800, 3600, 2400 and 1200.
(MENU) TIMER CAMERA RECORD ALARM DWELL REMOTE SYSTEM EVENT (REMOTE)
3. ID
Allow you to use RS-232 or RS-485 protocol to program different DQRs. [. . . ] When the external signal back to "High", it will stop recording action. ALARM RESET (INPUT)
To connect wire from ALARM RESET ( PIN 14 ) to GND ( PIN 9 ) connector, it can disable ALARM. An external signal to ALARM RESET ( PIN 14 ) can be used to reset both ALARM OUTPUT signal and DQR's internal buzzer. When alarm has been triggered, signal becomes "Low", and it will stop all alarm activities. [. . . ]