User manual WHIRLPOOL HBN G730 W INSTRUCTION FOR USE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WHIRLPOOL HBN G730 W. We hope that this WHIRLPOOL HBN G730 W user guide will be useful to you.


WHIRLPOOL HBN G730 W INSTRUCTION FOR USE: Download the complete user guide (4465 Ko)

You may also download the following manuals related to this product:

   WHIRLPOOL HBN G730 W SCHEDA PROGRAMMI (758 ko)
   WHIRLPOOL HBN G730 W CUADRO DE MANDOS (764 ko)
   WHIRLPOOL HBN G730 W PROGRAM CHART (754 ko)

Manual abstract: user guide WHIRLPOOL HBN G730 WINSTRUCTION FOR USE

Detailed instructions for use are in the User's Guide.

[. . . ] NUTID HGA3K GB IT PT ES GR ES GB IT PT ES GB ENGLISH IT ITALIANO PORTUGUÊS PT ESPAÑOL ES ΕΛΛΗΝΙΚΑ 4 17 31 45 59 Language, Lingua, Idioma, Idioma, Γλώσσα Country, Paese, País, País, Χώρα ENGLISH 4 Safety information Product description Daily use Helpful hints and tips Maintenance and cleaning What to do if Table of contents Your safety and the safety of others are very important. This manual and the appliance itself provide important safety messages, to be read and observed at all times. This is the safety alert symbol, pertaining to safety, which alerts users to potential hazards to themselves and others. All safety messages will follow the safety alert symbol and either the terms: DANGER Indicates a hazardous situation which, if not avoided, will cause serious injury. [. . . ] Failure to comply with these instructions may compromise the safety and quality of the product. ENGLISH 9 Injector table Category II2H3+ Type of gas used Type of burner Injector Nominal Nominal marking heating consumcapacity ption kW 140 97 74 B 3, 50 1, 65 1, 00 333 l/h 157 l/h 95 l/h Reduced Gas pressure heat (mbar) capacity kW min. 1, 55 0, 35 0, 30 NATURAL GAS (Methane) G20 wok semi-rapid auxiliary 17 20 25 LIQUEFIED PETROLEUM GAS (Butane) G30 wok semi-rapid auxiliary 93 65 50 3, 50 1, 65 1, 00 254 g/h 120 g/h 73 g/h 1, 55 0, 35 0, 30 20 28 30 35 LIQUEFIED PETROLEUM GAS (Propane) G31 wok semi-rapid auxiliary 93 65 50 3, 50 1, 65 1, 00 250 g/h 1 g/h 18 71 g/h 1, 55 0, 35 0, 30 25 37 45 Type of gas used Model configuration Nominal heating Total nominal capacity kW consumption Air necessary (m3) for combustion 1 m3 of gas 9, 52 30, 94 23, 80 G20 20 mbar G30 28-30 mbar G31 37 mbar 3 gas 3 gas 3 gas 6, 15 6, 15 6, 15 585 l/h 447 g/h 439 g/h Electric Power: 230 V ~ 50 Hz ENGLISH 10 Technical data Dimensions Width (mm) Height (mm) Length (mm) Voltage (V) The technical information are situated in the rating plate on the bottom side of the appliance and in the energy label. 770 47 350 230 After unpacking the hob, make sure that it has not been damaged during transport. In the event of problems, contact the dealer or your nearest After-sales Service. Technical information for the installer -- This product can be embedded in a worktop 20 to 60 mm thick. -- If there is no oven beneath the hob, insert a separator panel that has a surface at least equal to the opening in the work surface. This panel must be positioned at a maximum distance of 150 mm below the upper surface of the work surface but, in no case less than 20 mm from the bottom of the hob. -- Before installation, make sure that: -- the local gas delivery conditions (nature and pressure) are compatible with the settings of the hob (see the rating plate and injector table); -- the outer surfaces of the furniture or appliances adjacent to the hob are heat Installation resistant according to local regulations; -- This appliance is not connected to a fume exhaust device. It shall be installed in accordance with current installation regulations. Particular attention shall be given to the relevant requirement regarding ventilation. -- Combustion products are discharged outdoors through specific hoods or wall and/or window mounted electrical fans. gas connection This operation must be performed by a qualified technician. The gas supply system must comply with local regulations to the relavant gas standard. -- You can find specific local regulations for some countries in the paragraph -- “Reference to Local Regulations”. If no information concerning your Country is given, please ask details to a qualified technician. Remove the information label and keep it with the instructions booklet. Use pressure regulators suitable for the gas pressure indicated in the Instruction. -- The gas nozzles must be changed by After Sales Service or a qualified technician. -- Nozzles not supplied with the appliance must be ordered from After Sales Service. NOTE: when liquid petroleum gas is used (G30/G31), the minimum gas setting screw must be tightened as far as it will go. IMPORTANT: should you experience difficulty in turning the burners knobs, please contact the After Sales Service for the replacement of the burner tap if found to be faulty. [. . . ] Unless such damages can be proved to have been caused by production faults. € Cases where no fault could be found during a technician’s visit. € Repairs not carried out by our appointed service providers and/or an authorized service contractual partner or where nonoriginal parts have been used. € Repairs caused by installation which is faulty or not according to specification. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL HBN G730 W




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL HBN G730 W will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.