User manual WHIRLPOOL WRF540CWBW WARRANTY INFORMATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WHIRLPOOL WRF540CWBW. We hope that this WHIRLPOOL WRF540CWBW user guide will be useful to you.


WHIRLPOOL WRF540CWBW WARRANTY INFORMATION: Download the complete user guide (93 Ko)

You may also download the following manuals related to this product:

   WHIRLPOOL WRF540CWBW ENERGY GUIDE (118 ko)
   WHIRLPOOL WRF540CWBW DIMENSION GUIDE (156 ko)
   WHIRLPOOL WRF540CWBW USE & CARE GUIDE (1539 ko)

Manual abstract: user guide WHIRLPOOL WRF540CWBWWARRANTY INFORMATION

Detailed instructions for use are in the User's Guide.

[. . . ] 8 Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Component Description . 31 Parts lists and wiring diagrams are in the center of this manual, printed on yellow paper. December, 1988 Page 1 WRF540CWBW FOR THE INSTALLER BACK VIEW: AIR COOLED Note: Allow 6" behind and 6" above either unit for air circulation, utility connections, and service. ELECTRICAL INLET BACK VIEW: WATER COOLED ELECTRICAL INLET WATER INLET 9. 5" 5. 25" 3" 5. 25" 3" 7. 3" 9. 43" WATER INLET 3/8" FLARE DRAIN 3/4" FPT Condenser Inlet 3/8" FPT 2. 1" 5. 7" 2. 9" Condenser Drain 1/2" FPT 3. 4" DRAIN 3/4" FPT 4. 9" 7. 46" The WRF540CWBW is designed to fit the following Scotsman storage bins: B590 and extensions (with bin top KBT18) BH800 using bin top KBT15 (one unit). When installing a new system, check to be sure that you have everything you need before beginning: Correct Bin Correct Ice Machine Correct Bin Top (if required) All kits, legs, and information required for the specific job. [. . . ] The water should be between 90-115 degrees F. December, 1988 Page 16 WRF540CWBW MAINTENANCE AND CLEANING ///////////////////////////WARNING///////////////////////////// Disconnect electrical power before beginning. ////////////////////////////////////////////////////////////////////////// 1. The bin control uses devices that sense light, therefore they must be kept clean enough so that they can "see". At least twice a year, remove the bin control sensors from the base of the ice chute, and wipe the inside clean, as illustrated. The ice machine senses water level by a probe located in the water reservoir. At least twice a year, the probe should be removed from the reservoir, and the tip wiped clean of mineral buildup. PULL UP TO REMOVE PROBE ICE LEVEL SENSORS: SLIDE TO REMOVE CLEAN THE LIGHT SENSORS RESERVOIR Inspect the assembly, looking for wear. Check and tighten all bolts and screws. CLEAN THE WATER LEVEL PROBE ICE SWEEP /////////////////////////////////////////// CAUTION: THE TIP IS MADE OF GLASS ////////////////////////////////////////// SPANNER WRENCH 3. The bearing in the breaker should also be checked at least two times per year. Check the bearing by: · removing the ice chute cover · unscrewing the ice sweep · removing the water shed · using a spanner wrench and unscrewing the breaker cover. · unscrewing the auger stud December, 1988 Page 17 BREAKER COVER WRF540CWBW MAINTENANCE: Air Cooled ///////////////////////////WARNING///////////////////////////// Disconnect electrical power before beginning. ////////////////////////////////////////////////////////////////////////// 5. Check for a Thermostatic Expansion Valve that does not open, if defective, replace it. Check the high pressure cut out, if closed go to F, if open check 1. The pressure control opens at 450 psig. Check the high side pressure, reset the control, and observe: on water cooled, that water soon begins to flow from the condenser drain; or, on air cooled, that the fan is forcing air through the condenser. If the unit trips out on pressures below 450 psig, replace the control. If the pressures rise above the trip out point, and the unit shuts down: a. Check for adequate water flow on water cooled, if adequate, clean the interior of the condenser. If the pressures are still too high replace the water regulating valve. If the air flow is poor because of the installation, advise the user that the unit should be moved, or the air around it kept cooler. Check that the fan blades are clean, and the fan secure to the fan motor shaft. It opens from excess pressure of ice inside the ice chute: this should only happen when the machine does not shut off when the ice storage bin is full. This switch will reset when the ice melts, but the machine will not resart until the reset switch on the circuit board is pressed. [. . . ] /////////////////////////////////////////////////////////////////////////// To Remove and Repair the Gearmotor Assembly: (Assuming that the procedures through removal of the water seal have been performed. ) 1. Unscrew the 4 cap screws holding the gearmotor to the base of the machine. COVER & OUTPUT GEAR To Inspect the Gearmotor ASSEMBLY A) Remove the cap screws holding the gearmotor halves together and pry the two cases apart. B) To lift off the cover, lift up until you can feel internal contact, then pull the cover towards the output gear end. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL WRF540CWBW




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL WRF540CWBW will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.