User manual WHIRLPOOL WRS325FDAB WARRANTY INFORMATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WHIRLPOOL WRS325FDAB. We hope that this WHIRLPOOL WRS325FDAB user guide will be useful to you.


WHIRLPOOL WRS325FDAB WARRANTY INFORMATION: Download the complete user guide (85 Ko)

You may also download the following manuals related to this product:

   WHIRLPOOL WRS325FDAB ENERGY GUIDE (403 ko)
   WHIRLPOOL WRS325FDAB DIMENSION GUIDE (88 ko)
   WHIRLPOOL WRS325FDAB USE & CARE GUIDE (1362 ko)
   WHIRLPOOL WRS325FDAB INSTALLATION GUIDE (793 ko)

Manual abstract: user guide WHIRLPOOL WRS325FDABWARRANTY INFORMATION

Detailed instructions for use are in the User's Guide.

[. . . ] 32 Parts lists and wiring diagrams are in the center of this manual, printed on yellow paper. This manual was printed on recycled paper. Note the Warning symbol where it appears, it marks a possible hazard. January 1994 Page 1 WRS325FDAB & FME2400 FOR THE INSTALLER BACK VIEW The FME2400 and the WRS325FDAB are designed to fit the following Scotsman storage Condenser Inlet (W/C): 3/8" FPT bins: B90 and extensions (with bin top KBT18) BH800 no bin top required. 3" When installing a new system, check to be sure that you have everything you need before beginning: Correct Bin Correct Ice Machine Correct Bin Top (if required) TOP VIEW All kits, legs, and information required for the specific job. Note: Allow 6" behind and 6" above the unit for air circulation, utility connections, and service. 14. 9" 15. 8" 18. 74" 18. 9" Electrical Inlet Water Inlet 3/8" Flare Drain 3/4" FPT Condenser Drain (W/C): 1/2" FPT 6" Ice Chute 2. 64" x 6. 2" 18. 28" The normal finish for the ice machine is enamel-sandalwood. [. . . ] Slowly pour the cleaning solution into the water reservoir until it is full. As the ice maker begins to use water from the reservoir, continue to add more cleaning solution to maintain a full reservoir. After all of the cleaning solution has been added to the reservoir, and the reservoir is nearly empty, switch the master switch to OFF. After draining the reservoir, as in step 6, wash and rinse the water reservoir. January 1996 Page 16 WRS325FDAB & FME2400 MAINTENANCE AND CLEANING These steps must be followed for both systems. ICE LEVEL SENSORS: SLIDE TO REMOVE Disconnect electrical power before beginning. 1. The bin control uses devices that sense light, therefore they must be kept clean enough so that they can ``see''. At least twice a year, remove the bin control sensors from the base of the ice chute, and wipe the inside clean, as illustrated. The ice machine senses water level by a probe located in the water reservoir. At least twice a year, the probe should be removed from the reservoir, and the tip wiped clean of mineral build-up. PULL UP TO REMOVE PROBE CLEAN THE LIGHT SENSORS RESERVOIR Inspect the assembly, looking for wear. Check and tighten all bolts and screws. CLEAN THE WATER LEVEL PROBE ICE SWEEP /////////////////////////////////////////// CAUTION: THE TIP IS MADE OF GLASS ////////////////////////////////////////// 3. The bearing in the breaker should also be checked at least two times per year . Check the bearing by: ·removing the ice chute cover BREAKER COVER ·unscrewing the ice sweep ·removing the water shed ·unscrewing the breaker cover. Check for a Thermostatic Expansion Valve that does not open, if defective, replace it. Check the high pressure cut out, if closed, go to F; if open check: 1. Check the high side pressure, reset the control, and observe: on water cooled, that water soon begins to flow from the condenser drain; or, on air cooled, that the fan is forcing air through the condenser. If the unit trips out on pressures below 400 psig, replace the control. If the pressures rise above the trip out point, and the unit shuts down: a. Check for adequate water flow on water cooled, if adequate, clean the interior of the condenser. If the pressures are still too high replace the water regulating valve. If the air flow is poor because of the installation, advise the user that the unit should be moved, or the air around it kept cooler. Check that the fan blades are clean, and the fan secure to the fan motor shaft. The machine will not run if there is not enough water in the reservoir. See the next step. January 1994 Page 20 WRS325FDAB & FME2400 SERVICE DIAGNOSIS: Condition - No Ice Being Produced STATUS: NOTHING OPERATES G. [. . . ] A) Remove the cap screws holding the gear motor case halves together and pry the two cases apart. B) To lift off the cover, lift up until you can feel internal contact, then pull the cover towards the output gear end, and then lift the cover (with drive motor attached) up and away from the gear motor case. Note: The gearcase cover, output gear, bearings and output shaft are a pressed together assembly. January 1994 Page 29 WRS325FDAB & FME2400 REMOVAL AND REPLACEMENT Removing Condenser Fan Motor Assembly FAN MOTOR ASSEMBLY Disconnect electrical power before beginning. CAP SCREWS LOCATING PINS FAN MOTOR WIRE 1. Remove two hex head bolts from top end of fan motor assembly, (see the illustration). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL WRS325FDAB




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL WRS325FDAB will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.