User manual ZIBRO P 28

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZIBRO P 28. We hope that this ZIBRO P 28 user guide will be useful to you.


ZIBRO P 28 : Download the complete user guide (685 Ko)

You may also download the following manuals related to this product:

   ZIBRO P 28 (691 ko)
   ZIBRO P 28 (687 ko)
   ZIBRO P 28 (686 ko)
   ZIBRO P 28 (692 ko)
   ZIBRO P 28 (685 ko)
   ZIBRO P 28 (710 ko)
   ZIBRO P 28 (686 ko)
   ZIBRO P 28 (689 ko)
   ZIBRO P 28 (689 ko)

Manual abstract: user guide ZIBRO P 28

Detailed instructions for use are in the User's Guide.

[. . . ] P 28 2 6 5 3 FIN GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO MANUEL D'UTILISATION KYTTOHJE OPERATING MANUAL 4 16 28 40 52 64 4 2 ALLGEMEINE SICHERHEIT Aus Sicherheitsgrnden bitten wir Sie, die Bedienungsanleitung vor Inbetriebnahme sorgfltig zu lesen!Personen, die mit der Bedienungsanleitung nicht vertraut sind, drfen das Gert nicht bedienen. Nicht selbst reparieren. A 6 SIKKERHED GENERELT Ls denne brugsanvisning grundigt igennem af hensyn til sikkerheden!Personer, som ikke er fortrolige med brugsanvisningens indhold, m ikke anvende dette klimaanlg. [. . . ] Take care to prevent any bow or bend in the exhaust hose. C OPERATION 1 Insert the plug into the wall outlet. 2 Press the 3 With -button to switch on the air conditioner. -button you can change the operating mode of the unit. -button the following modes appear: By pressing the Cooling, the green light lits. COOLING When the unit is in the cooling mode, the following functions apply: The fan speed can be adjusted by pressing the Maximum setting. The temperature can be set by pressing the and buttons, anywhere between 16C en 32C. The display will show the set temperature for 15 seconds and the "set temp" will light up. Fifteen seconds after setting the required temperature, the display will show the room temperature. -button It depends on the environment whether the required temperature will be reached. It is not a malfunction of the air conditioner if the room temperature remains above the "set temp". 4 68 DEHUMIDIFYING When the unit is primarily used as a dehumidifier, then please follow these instructions: Do not connect the air exhaust hose and let the warm air go back into the room. Connect a drainage hose onto the permanent drain connector on the back of the unit (refer to Chapter G). You must connect a drain tube to the water outlet (refer to Chapter G). cannot be When the unit is in the dehumidifying mode, the fan speed adjusted when the temperature is below 25C. Adjusting of the temperature setting does not have any effect when in dehumidifying mode. AIR CIRCULATION In this mode the unit only circulates air; the unit will not cool or dehumidify. The air entering the unit is not cooled or dehumidified, but is filtered. When the unit is in this mode, the following functions apply: The fan speed can be adjusted by pressing the Maximum setting. 4 When the unit is switched off the most recent setting will be stored in memory. 5 The timer function allows you to switch the unit on or off at a certain time. TO SWITCH ON THE UNIT AT A CERTAIN TIME Ensure that the unit is set in the required operating mode Switch off the unit by pressing the properly inserted into the wall outlet. Ensure that the plug is -button When the set time has expired the unit will switch on. TO SWITCH OFF THE UNIT AT A CERTAIN TIME When the unit is operating in the required mode press the The light "Timer set" will flash. -button. NOTE! The compressor has been set so that it starts functioning three minutes after the (re)start of the air conditioner. The cooling will switch off when the room temperature is lower than the set one. [. . . ] For maintenance of the filters, refer to Chapter D "Air Filter". NOTE! Never use the air conditioner without screenfilter. I STORAGE 1 Empty the internal water container (refer to Chapter F) 2 Clean and replace the mesh filter (see also chapter D). 3 Put the unit in air circulation mode for a couple of hours to ensure that the inside becomes completely dry. 4 Store cable as shown, protect the unit against dust and store in a dry place not accessible to children. 4 73 J TROUBLE SHOOTING Problem The unit does not function Water tank indicator is on In direct sunlight Windows or doors open, many people or heat source in room Dirty filter Air inlet or air outlet blocked Room temperature lower than selected value The unit is noisy Unit stands uneven The compressor does not work Overheat protection probably activated Distance too great Remote control does not function Remote control signal not detected by control panel Batteries empty Cause No power supply Solution Connect to a functioning outlet and switch on Empty the internal water container (refer to Chapter F) Close curtains Close doors and windows, or place an extra air conditioner Clean or replace filter Remove blockage Change temperature selection Place on even surface (less vibrations) Wait 3 minutes until the temperature has decreased, and turn on the unit again Make sure the remote control is correctly aimed at the control panel Replace the batteries The unit does not seem to perform Never try to repair or dismantle the air conditioner yourself. Incompetent repairs result in loss of warranty and can endanger the user. K GUARANTEE CONDITIONS The air conditioner is supplied with a 24-month guarantee, commencing on the date of purchase. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZIBRO P 28




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZIBRO P 28 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.