User manual ZIBRO S1564

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZIBRO S1564. We hope that this ZIBRO S1564 user guide will be useful to you.


ZIBRO S1564 : Download the complete user guide (737 Ko)

You may also download the following manuals related to this product:

   ZIBRO S1564 (739 ko)

Manual abstract: user guide ZIBRO S1564

Detailed instructions for use are in the User's Guide.

[. . . ] S1523 - S1526 - S1534 S1550 - S1564 4 TR OPERATING MANUAL KULLANIM KILAVUZU 2 20 Dear Sir, Madam, Congratulations on the purchase of your Zibro airconditioner. You have acquired a high quality product that, if used responsibly, will give you many years of pleasure. Please read these instructions for use first in order to ensure the maximum life span of your airconditioner. On behalf of the manufacturer, we provide a 24-month guarantee on all material and production defects. [. . . ] If it is difficult to warm the room because of low outdoor temperature, use additional heating equipment. * For Dual and Triple models only Only one operation mode should be selected at a time for all the indoor units. (Different modes can not be concurrently selected for the indoor units. ) If one or two indoor units are already operating in a certain mode, another mode can not be selected for the other indoor units. When this happens, select the same mode as the other operating units. 4 11 Automatic operation In automatic operation the air conditioner selects the operation mode (cooling, dry, heating) according to the room temperature when it starts. The air conditioner will restart in the previous mode if autoHow to select operating mode Heating Dry Cooling Room temperature matic operation is resumed within 3 hours from the switchoff. Mode review The computer checks and compares the room temperature 5 minutes and 15 minutes apart after the compressor shuts off, and it will review the mode. Afterwards it is repeated every 10 minutes. Auto Recovery Function lf there is any power failure during operation, operation status before power failure is memorized. 3~4 minutes after power recover, the unit restarts automatically with previous operation status memorized. (3~4 minutes is protective time for compressor. ) ATTENTION Because of Auto Recovery Function, if shutting off the power supply during operation, the unit may restart irrespective your intention when turning on the power supply next time. If the unit is not to be used for a long time, shut off the power supply after terminating all operation with remote controller. Adjust the setting temperature by pressing the temperature setting button. When the mode is set at "AUTO" the fan speed changes automatically. The system will retain the previous setting conditions until next operation. , by pressing the operation mode NOTE If the selected mode by Automatic Operation does not suit you, set the operation mode (cooling, dry heating) with the Operation mode button. Even if you press the ON button after the stop, the air conditioner will not start operation for approx. of waiting. 4 12 Air flow adjustment Vertical adjustment During Cooling, Dry During Circulating, Operation Dry Operation The vertical louver will move automatically to the suitable position when ON/OFF button is pressed. Swing of air flow The vertical louver will keep moving within the range illustrated on the left, if the vertical louver button is pressed once. Fixing the air flow Direction If the louver button switch is pressed again, the vertical louver will be fixed and that position is memorized. From the next operation the louver will be set at previous position automatically. Approx. 45 degrees (70) (5 kW / 6. 4 kW Heat Pump models) NOTE! When the operation is off, the vertical louver closes the outlet automatically. In order to move the vertical louver, use wireless remote controller without fail. In case the louver does not work correctly, once stop the operation and turn on again. [. . . ] Then plug in again and push ON/OFF button on the remote control unit. 4 18 H GUARANTEE CONDITIONS The air conditioner is supplied with a 24-month guarantee, commencing on the date of purchase. All material and manufacturing defects will be repaired or replaced free of charge within this period. We expressly refuse all further damage claims, including claims for collateral damage. Repairs to or replacement of components within the guarantee period will not result in an extension of the guarantee. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZIBRO S1564




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZIBRO S1564 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.