User manual ZIBRO S1629

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZIBRO S1629. We hope that this ZIBRO S1629 user guide will be useful to you.


ZIBRO S1629 : Download the complete user guide (613 Ko)

You may also download the following manuals related to this product:

   ZIBRO S1629 (614 ko)
   ZIBRO S1629 (614 ko)
   ZIBRO S1629 (606 ko)
   ZIBRO S1629 (637 ko)

Manual abstract: user guide ZIBRO S1629

Detailed instructions for use are in the User's Guide.

[. . . ] S1629 - S1635 6 4 1 : TR BRUGSANVISNING OPERATING MANUAL GEBRUIKSAANWIJZING INSTRUKCJA OBSLUGI KULLANIM KILAVUZU 2 20 38 56 74 Dear Sir, Madam, Congratulations on the purchase of your airconditioner. You have acquired a high quality product that, if used responsibly, will give you many years of pleasure. Please read these instructions for use first in order to ensure the maximum life span of your airconditioner. On behalf of the manufacturer, we provide a 24-month guarantee on all material and production defects. [. . . ] , Heating or Dry , by pressing the NOTE! If the unit operates in cooling or dry for a long time in high humidity (i. e. , windows and doors are opened), dew and water drops may form on the indoor unit. If you set a low temperature for dry operation, you may feel the air flow is cold. During dry mode operation, the system performs the cooling operation until the room temperature reaches 1~2C above the setting temperature. Then it continues dry mode operation intermittently with fan speed at "LO", regardless of the designated speed. During dry operation, the indoor unit stops operating for 3 minutes when the room temperature reaches the setting temperature. During the heating operation, the outdoor unit may frost and heating capacity may be reduced. In this case, the unit stops its heating operation and conducts defrosting operation automatically. During the defrosting operation, the fans of the indoor and outdoor units stop. Unless the heat exchanger gets warm enough, the air will not flow out to prevent cold air. Automatic operation In automatic operation the air conditioner selects the operation mode (cooling, dry, heating) according to the room temperature when it starts. The air conditioner will restart in the previous mode if automatic operation is resumed within 3 hours from the switch-off. The computer checks and compares the room temperature regularly after the compressor shuts off, and will adapt the operating mode. 4 27 1. 4. Press the ON/OFF button Set the operation mode to Automatic "AUTO", by pressing the operation mode button Adjust the setting temperature by pressing the temperature setting buttons. When the mode is set at "AUTO" the fan speed changes automatically. NOTE If the selected mode by Automatic operation does not suit you, set the operation mode (cooling, dry, heating) with the operation mode button. Negative ion operation This function is available only when the air conditioner is operating. 1. 2. Press the ON/OFF button Press the ionizer button To stop negative ion operation, press the ionizer button. 4 28 Air flow adjustment Horizontal adjustment When the ON/OFF button is pressed, the horizontal louver will move automatically. During cooling, dry operation During circulation, heating operation Level Approx. The timer lamp of the indoor unit goes off. 4 30 "OFF Timer" Example: Set the "Off Timer" to 10 p. m. Press the "TIME ADJ" 3 times. 2. Adjust the time with the button. Hold the button to fast forward the time. 3. Press the "TIME ADJ" button once. The setting of "OFF Time" is complete and the present time appears. 4. Press the timer fixing button "ON". The "ON Time" is displayed for 2 seconds and then the present time appears. Cancelling "OFF Timer" Press the timer fixing button "OFF". The timer lamp of the indoor unit goes off. "SLEEP Timer" Pressing this button starts the timer mode that will stop the operation after the setting time. Press the "SLEEP" button during the operation. The setting time repeats the following mode by pressing the button: Continuous operation (Sleep Operation: OFF). The operation stops after passing the setting time. 4 31 Sleep Timer features During Cooling Operation The setting temperature rises 0. 6C after 30 minutes of Sleep Timer ON, and rises 0. 6C again after 30 minutes of the first temperature rise. During Heating Operation The setting temperature drops 0. 6C after 30 minutes of Sleep Timer ON, and drops 0. 6C again after 30 minutes of the first temperature drop. Emergency and test operation Emergency Operation The emergency operation is needed only when the remote control can not be used. [. . . ] Unusual odour. The sound of running water. A creaking sound. The sound may be caused by the expansion/shrinkage of the front panel as a consequence of temperature fluctuations. Condensation/mist is created when the air temperature in the Mist/moisture is expelled from the air outlet. room drops significantly due to the fact that cold air is expelled in the COOLING or DRY mode. The red compressor indicator flashes constantly and the fan in the indoor unit ceases to operate. The indicator light will go out within 10 minutes and the unit will return to the heating mode. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZIBRO S1629




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZIBRO S1629 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.