User manual ZIBRO SRE 230 E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZIBRO SRE 230 E. We hope that this ZIBRO SRE 230 E user guide will be useful to you.


ZIBRO SRE 230 E : Download the complete user guide (832 Ko)

You may also download the following manuals related to this product:

   ZIBRO SRE 230 E (831 ko)
   ZIBRO SRE 230 E (834 ko)
   ZIBRO SRE 230 E (830 ko)
   ZIBRO SRE 230 E (828 ko)
   ZIBRO SRE 230 E (828 ko)
   ZIBRO SRE 230 E (830 ko)

Manual abstract: user guide ZIBRO SRE 230 E

Detailed instructions for use are in the User's Guide.

[. . . ] For comfortable and safe heating ensure that there is sufficient ventilation. Note: To avoid unexpected shut off, we recommend to put a door or window ajar when the heater is operating. For each Zibro model the minimum size of space is specified in which you can use the heater safely, without additional ventilation (refer to Section P). If a particular room is smaller than the specified space, always leave a window or door slightly ajar ( 2. 5 cm). [. . . ] G). G: The TIMER indicator light indicates that the timer function has been switched on. 4 The timer will ensure that the room will have been heated to approximately the required temperature at the set time. G H In case of any malfunctioning the information display will tell you what is the matter. When you want to switch off the heater and ignite it again with the timer, all you have to do is press the TIMER key (refer to Section G). Press the button once to clear the timer setting. SWITCHING OFF THE HEATER There are two ways to switch off the heater. 2 Press the TIMER key , when you want to switch off the heater and ignite it again with the timer the next time. This not only switches off the heater, but it also activates the timer function. You can change the required time with the adjustment keys (refer to Section F). THE INFORMATION DISPLAY The information display not only serves as an indicator of the (set) time and temperature (sections C, E, and F), it also indicates any malfunctioning of the heater. The code on the information display tells you what is the matter: CODE INFORMATION Temperature within the heater too high. When this function is activated, the heater will automatically switch off, when the room temperature exceeds the set temperature by 3C. Subsequently, when the room temperature has dropped again to the set temperature, the heater will automatically switch on again. Activate the 'SAVE' I: When the SAVE function is activated, the heater will automatically switch on or off in order to remain within a specified temperature range. setting by pressing the appropriate key. will display on the information display (Fig. Without the 'SAVE' setting your heater will maintain the set temperature by approximation as well, by adjusting its heating capacity. 'SAVE' is an economy setting, which you can use when, for instance, you are not present in the room or to keep it frost-free. 4 48 K THE 'FUEL' INDICATOR LIGHT When the indicator light FUEL lights up, it means that there is only fuel left for 10 more minutes. The count-down of the remaining heating time can be seen in the information display (Fig. By pushing this button, the remaining you remove the fuel tank and refill it outside the living room (section B) or you push the button EXTENSION heating time will extend to 60 minutes. The heater will automatically switch J: When the FUEL indicator has appeared, the information display will show the number of minutes of fuel left in the tank. back to its lowest position. At the arrival of 10, you will hear an alarm signal every two minutes, warning you to refill the removable tank. The fuel indicator light will blink, while four lines (--:--) are blinking in the information display. Once the heater has used up all its fuel and extinguished, it will take some time, after the refill, before the heater is completely ready for use again. L THE 'VENT' INDICATOR When there is insufficient ventilation in the room, an intermittent buzzer will be heard (approximately once each 30 seconds) and the VENT indicator will be lit. When this signal is given, ensure that the ventilation of the room is improved (e. g. by opening a door or window a little more), to avoid that the heater shuts off. When the K: A blinking VENT indicator is a sign that you need extra ventilation. ventilation of the room is improved, the VENT indicator and buzzer will be deactivated. When there is still insufficient ventilation, the heater shuts off automatically. When this occurs, e- 1 1 is displayed and the VENT indicator is blinking. [. . . ] Ask you local council or dealer for expert advice on recycling. 4 51 DISTRIBUTED IN EUROPE BY PVG INTERNATIONAL b. v. i STERREICH PVG Austria VertriebsgmbH Salaberg 49 3350 HAAG tel: +43 7434 44867 fax: +43 7434 44868 email: pvgaustria@zibro. com e BELGI PVG Belgium NV/SA Industrielaan 55 2900 SCHOTEN tel: +32 3 326 39 39 fax: +32 3 326 26 39 email: pvgbelgium@zibro. com q SCHWEIZ PVG Schweiz AG Salinenstrasse 63 4133 PRATTELN tel: +41 61 337 26 51 fax: +41 61 337 26 78 email: pvgint@zibro. com 2 DEUTSCHLAND PVG Deutschland GmbH Siemensstrasse 31 47533 KLEVE tel: 0800 - 9427646 fax: +31 (0)412 648 385 email: pvgdeutschland@zibro. com 6 DANMARK Appliance A/S Blovstroed Teglvaerksvej 3 DK-3450 ALLEROED tel: +45 70 205 701 fax: +45 70 208 701 email: appliance@appliance-group. com 5 ESPAA PVG Espaa S. A. San Jos de Valderas II Comunidad "La Alameda" C/ Aurora Boreal, 19 28918 LEGANS (Madrid) tel: +34 91 611 31 13 fax: +34 91 612 73 04 email: pvgspain@zibro. com 3 FRANCE PVG France SARL 4, Rue Jean Siblius B. P. 185 76410 SOTTEVILLE SOUS LE VAL +33 2 32 96 07 47 tel: fax: +33 0 820 34 64 84 email: pvgfrance@zibro. com F I N SUOMI Appliance Finland Oy Piispantilankuja 6C 02240 ESPOO +358 9 4390 030 tel: fax: +358 9 4390 0320 email: appliance@appliance-group. com 4 UNITED KINGDOM Scott Brothers Ltd. The Old Barn, Holly House Estate Cranage, Middlewich, CW10 9LT UK tel. : +44 1606 837787 fax: +44 1606 837757 email: sales@scottmail. co. uk > ITALIA PVG Italy SRL Via Niccol Copernico 5 50051 CASTELFIORENTINO (FI) +39 571 628 500 tel: fax: +39 571 628 504 email: pvgitaly@zibro. com u NORGE Appliance Norge AS Vogellunden 31 1394 NESBRU tel: +47 667 76 200 fax: +47 667 76 201 email: appliance@appliance-group. com 1 NEDERLAND PVG International B. V. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZIBRO SRE 230 E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZIBRO SRE 230 E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.